WRLS-Driven Robustness Enhancement of Nine-Switch Unified PV-DVR Systems Under Unbalanced Grid Conditions

Jefferson Rafael Pereira De Assis, Darlan Alexandria Fernandes, Maurício Beltrão De Rossiter Corrêa, Alfeu Joãozinho Sguarezi Filho, Fabiano Fragoso Costa, Edison Roberto Cabral Da Silva

IEEE Access · 2026 · 14 · 81113-81129

DOI: 10.1109/access.2026.3697603 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Jefferson Rafael Pereira De Assis und 5 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Integrated systems combining grid-connected photovoltaic (PV) plants and dynamic voltage restorers (DVR) via nine-switch inverters (NSI) offer a compact and cost-effective solution for power quality enhancement. However, conventional control strategies for such unified topologies, typically based on synchronous reference frame transformations, fail to maintain load voltage stability during asymmetrical grid disturbances. This work proposes an enhanced control block specifically designed to provide the PV-DVR system with robustness against asymmetrical faults at the point of common coupling (PCC). The methodology utilizes the instantaneous decomposition into sequence components (IDSC) technique optimized by a weighted recursive least squares (WRLS) algorithm to estimate positive, negative, and zero sequence components in real-time. These components serve as inputs to a novel control loop that independently regulates the compensation voltage for each phase. The main contribution of this study resides in the synergistic integration of WRLS-driven sequence estimation with a dedicated control architecture, specifically devised to maintain the nominal load voltage in PV-DVR systems employing NSI topologies under asymmetrical fault conditions. The proposed strategy was validated through real-time simulations using the OP5700 simulator. Results for single-phase and two-phase-to-ground faults demonstrate that the load voltage is fully restored within approximately 10 ms (half a cycle), with no violations of the ITI (CBEMA) curve limits. Compared to the traditional setup, the proposed control markedly improves system reliability, ensuring nominal voltage delivery even under severe unbalanced conditions.

Förderung

  • Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior

Zitieren

APA

Assis, J. R. P. D., Fernandes, D. A., Corrêa, M. B. D. R., Filho, A. J. S., Costa, F. F., & Silva, E. R. C. D. (2026). WRLS-Driven Robustness Enhancement of Nine-Switch Unified PV-DVR Systems Under Unbalanced Grid Conditions. IEEE Access, 14, 81113-81129. https://doi.org/10.1109/access.2026.3697603

Vancouver

Assis JRPD, Fernandes DA, Corrêa MBDR, Filho AJS, Costa FF, Silva ERCD. WRLS-Driven Robustness Enhancement of Nine-Switch Unified PV-DVR Systems Under Unbalanced Grid Conditions. IEEE Access. 2026;14:81113-81129. doi:10.1109/access.2026.3697603

BibTeX
@article{Assis2026,
  author = {Assis, Jefferson Rafael Pereira De and Fernandes, Darlan Alexandria and Corrêa, Maurício Beltrão De Rossiter and Filho, Alfeu Joãozinho Sguarezi and Costa, Fabiano Fragoso and Silva, Edison Roberto Cabral Da},
  title = {WRLS-Driven Robustness Enhancement of Nine-Switch Unified PV-DVR Systems Under Unbalanced Grid Conditions},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {81113--81129},
  doi = {10.1109/access.2026.3697603}
}
Kostenlos starten →