Performance Comparison of a Dynamic Voltage Restorer Using DQ and PQ Control Methods
IEEE Access · 2026 · 14 · 92193-92208
DOI: 10.1109/access.2026.3693763 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Saad F. Algahtani und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Research and Graduate Studies at King Khalid University through Large Research Project.
Abstract (Originalsprache)
In the dominion of power systems, voltage sags and swells are transient disturbances that can significantly impact the performance and stability of the grid. This issue must be addressed with robust control techniques to have good performance, with low harmonic and stable operation of the power system. Many techniques for instance, dynamic voltage restorers (DVRs) and series active power filters were proposed based on conventional theories having merits and demerits. This research aims to provide a comprehensive comparison between two DVR control techniques. The First technique is the modified instantaneous reactive power theory (PQ), whereas the second is modified synchronous stationary frame (DQ) method under various sag and swell voltage conditions. The extracted components of the grid voltage positive sequence and load current negative sequence form the basis of the improved approaches to detect the disturbance and generate the control signal of the DVR. The study encompasses Unbalanced load voltage with 80% sag, unbalanced load voltage with 70% swell, balanced 80% voltage sag, and a 50% balanced load change are the five different operating conditions. Both control approaches, with their modified versions, are mathematically represented and evaluated under different specified severe power quality conditions. The methods are performed in MATLAB/Simulink environment and implemented experimentally using DSPACE DS1104 controller-based system to provide a comparison analysis and validate the system’s voltage profile and harmonic distortion performance study. The obtained results and analysis illustrate the effectiveness of the proposed two control methods. Each technique demonstrates their effectiveness for addressing the power quality issue.
Förderung
- Deanship of Research and Graduate Studies at King Khalid University through Large Research Project
Zitieren
APA
Algahtani, S. F., Salem, E. Z. M., Irshad, S. M., & Azazi, H. Z. (2026). Performance Comparison of a Dynamic Voltage Restorer Using DQ and PQ Control Methods. IEEE Access, 14, 92193-92208. https://doi.org/10.1109/access.2026.3693763
Vancouver
Algahtani SF, Salem EZM, Irshad SM, Azazi HZ. Performance Comparison of a Dynamic Voltage Restorer Using DQ and PQ Control Methods. IEEE Access. 2026;14:92193-92208. doi:10.1109/access.2026.3693763
BibTeX
@article{Algahtani2026,
author = {Algahtani, Saad F. and Salem, Elbarbary Z. M. and Irshad, Shaik Mohammad and Azazi, Haitham Z.},
title = {Performance Comparison of a Dynamic Voltage Restorer Using DQ and PQ Control Methods},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {92193--92208},
doi = {10.1109/access.2026.3693763}
}
EUVIMED