Performance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System
IEEE Access · 2026 · 14 · 71475-71493
DOI: 10.1109/access.2026.3692287 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Nisha Kumari und 4 weiteren Autor:innen. Die Arbeit nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
An enhanced type-2 fuzzy integral–derivative plus proportional-derivative (T2FID+PD) controller is suggested for mitigating frequency deviations in a triple-area hybrid power system (HPS). Optimal controller settings are computed using the African vulture optimizer (AVO). The thermal PS & distributed renewable generation (DRG) are interconnected in Area-1. This DRG unit comprises wind-turbine & solar-photovoltaic generation. The thermal & gas and thermal & nuclear facilities are interconnected in Area-2 and Area-3, respectively. The nonlinearities, including generation rate constraints (GRC), boiler dynamics (BD), and governor dead band (GDB), are also modeled. Moreover, the performance evaluation of an AVO-based tuned T2FID+PD control is compared with its contemporaries. Also, the effect of integrating electric vehicles is studied. Additionally, the developed controller’s robustness to parameter variations in power systems is ascertained. Finally, the impact of deregulation is studied by simulating nominal, unilateral, and contract violation scenarios. Amid deregulation, the impact of communication latency and changes in distribution participation are analyzed. The AVO-tuned T2FID+PD controller shows enhanced frequency regulation capabilities than its contemporaries as demonstrated through simulation studies on IEEE 39 Bus system. The suggested controller lowers settling time of frequency variation by 92.20%, 92.09%, and 92.19%; overshoot by 97.00%, 7.94%, and 96.08%; and undershoot by 89.68%, 93.37%, and 89.17% compared to several well-known studies in the literature.
Zitieren
APA
Kumari, N., Kumar, V., Aryan, P., Raja, G. L., & Hote, Y. V. (2026). Performance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System. IEEE Access, 14, 71475-71493. https://doi.org/10.1109/access.2026.3692287
Vancouver
Kumari N, Kumar V, Aryan P, Raja GL, Hote YV. Performance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System. IEEE Access. 2026;14:71475-71493. doi:10.1109/access.2026.3692287
BibTeX
@article{Kumari2026,
author = {Kumari, Nisha and Kumar, Vivek and Aryan, Pulakraj and Raja, G. Lloyds and Hote, Yogesh V.},
title = {Performance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {71475--71493},
doi = {10.1109/access.2026.3692287}
}