EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental Validation of Precision Control in Low-Friction Seal-Type and Polymer-Coated Seal-Less Hydraulic Actuators

Jaeyoung Kim, Kyung-Rok Kim, Dongwoo Kang, Hyunchang Kim

IEEE Access · 2026 · 14 · 69578-69590

DOI: 10.1109/access.2026.3691254 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Jaeyoung Kim und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Institute of Machinery and Materials through the Government-Funded Research Program, National Research Council of Science and Technology (NST) grant by Korean Government.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents an experimental investigation of frequency-response characteristics and precision motion control performance in low-friction seal-type and polymer-coated seal-less hydraulic actuators operating under high-pressure conditions. Instead of relying on detailed parametric modeling, frequency-response-function (FRF) analysis is utilized to identify dominant resonance characteristics and bandwidth constraints arising from coupled hydraulic–mechanical dynamics under realistic operating conditions. Based on the measured FRFs, a feedback–feedforward control strategy with resonance attenuation is implemented to achieve stable and repeatable precision motion within practically achievable closed-loop bandwidths. Precision control performance is evaluated through sinusoidal tracking and micro-stepping control experiments under closed-loop bandwidths (CBW) of 10, 20, and 50 Hz. In sinusoidal tracking, the polymer-coated seal-less actuator reduces tracking error near velocity reversal points under identical operating conditions. In micro-stepping operation, the steady-state positioning accuracy is primarily determined by the selected control bandwidth, while the influence of actuator structure is relatively limited. Dual-actuator gap control experiments further demonstrate micrometer-level dynamic gap tracking and sub-micrometer-level steady-state gap control, confirming the applicability of the proposed framework to synchronized multi-actuator hydraulic systems.

Förderung

  • Korea Institute of Machinery and Materials through the Government-Funded Research Program
  • National Research Council of Science and Technology (NST) grant by Korean Government

Zitieren

APA

Kim, J., Kim, K., Kang, D., & Kim, H. (2026). Experimental Validation of Precision Control in Low-Friction Seal-Type and Polymer-Coated Seal-Less Hydraulic Actuators. IEEE Access, 14, 69578-69590. https://doi.org/10.1109/access.2026.3691254

Vancouver

Kim J, Kim K, Kang D, Kim H. Experimental Validation of Precision Control in Low-Friction Seal-Type and Polymer-Coated Seal-Less Hydraulic Actuators. IEEE Access. 2026;14:69578-69590. doi:10.1109/access.2026.3691254

BibTeX
@article{Kim2026,
  author = {Kim, Jaeyoung and Kim, Kyung-Rok and Kang, Dongwoo and Kim, Hyunchang},
  title = {Experimental Validation of Precision Control in Low-Friction Seal-Type and Polymer-Coated Seal-Less Hydraulic Actuators},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {69578--69590},
  doi = {10.1109/access.2026.3691254}
}
Kostenlos starten →