EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Differential Flatness of Grid-Connected EV Charging Stations With LCL Filters: Realizability Constraints and Trajectory Planning

Joanna Piasek-Skupna, Michał Skupny

IEEE Access · 2026 · 14 · 88068-88082

DOI: 10.1109/access.2026.3688792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Joanna Piasek-Skupna und 1 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre, Poland, through the research project “Analysis of Applicability of Flatness-Based Control for Nonlinear Underactuated Systems,”, PUT Internal Grant.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Grid-connected electric vehicle charging stations (EVCS) commonly employ LCL filters for harmonic attenuation. Yet, trajectory planning methods typically rely on single-inductance models without providing a formal justification for neglecting filter dynamics. This paper establishes the differential flatness of the complete bidirectional EVCS, comprising a DC/DC converter, DC bus, voltage-source converter (VSC), and LCL filter, in the synchronous $dq$ reference frame. The flat outputs are non-trivial linear combinations of the grid-side current and filter capacitor voltage, coupling states across the LCL structure. From this flatness property, seven closed-form realizability constraints are derived, ordered by derivative level from zero to three, which guarantee the physical feasibility of any candidate trajectory without time-domain simulation. The highest-order constraint (the modulation index limit) is expressed in a compact matrix form with eight coefficients that are explicit functions of the filter parameters. A parameter-free model reduction result shows that the simplified single-inductance model reproduces the full LCL constraints to a relative error of $O(\varepsilon + \delta)$ , where $\varepsilon $ and $\delta $ depend only on the ratios of planning bandwidth and grid frequency to the filter resonance frequency. Trajectory optimization in the native LCL flat coordinates with all seven constraints enforced produces trajectories that a standard $dq$ -frame PI controller with active damping tracks with sub-percent RMSE under nominal conditions and without modulation saturation, even under 20% parameter mismatch. A Monte Carlo study (±10–20% perturbation on all plant parameters, 50 trials per level) shows that modulation feasibility holds in every stable closed-loop trial. Grid voltage is identified as the dominant sensitivity, with a stability boundary consistent with the planner’s constraint margin. These results validate the proposed constraint formulation and support a practical two-stage workflow: plan using the reduced model and verify against the full LCL constraints.

Förderung

  • National Science Centre, Poland, through the research project “Analysis of Applicability of Flatness-Based Control for Nonlinear Underactuated Systems,”
  • PUT Internal Grant

Zitieren

APA

Piasek-Skupna, J., & Skupny, M. (2026). Differential Flatness of Grid-Connected EV Charging Stations With LCL Filters: Realizability Constraints and Trajectory Planning. IEEE Access, 14, 88068-88082. https://doi.org/10.1109/access.2026.3688792

Vancouver

Piasek-Skupna J, Skupny M. Differential Flatness of Grid-Connected EV Charging Stations With LCL Filters: Realizability Constraints and Trajectory Planning. IEEE Access. 2026;14:88068-88082. doi:10.1109/access.2026.3688792

BibTeX
@article{PiasekSkupna2026,
  author = {Piasek-Skupna, Joanna and Skupny, Michał},
  title = {Differential Flatness of Grid-Connected EV Charging Stations With LCL Filters: Realizability Constraints and Trajectory Planning},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {88068--88082},
  doi = {10.1109/access.2026.3688792}
}
Kostenlos starten →