Risk-Aware Data Center BESS Dispatch With MILP, Machine Learning, and Stochastic Outage Simulations

Hasan Iqbal, Arif Sarwat

IEEE Access · 2026 · 14 · 60593-60615

DOI: 10.1109/access.2026.3682635 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Hasan Iqbal und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data centers increasingly adopt behind-the-meter (BTM) battery energy storage systems (BESS) to reduce electricity bills dominated by demand charges, while simultaneously facing strict service-continuity requirements under stochastic grid outages. A core challenge is that aggressive dispatch for peak shaving and arbitrage can erode state-of-charge (SOC) headroom, increasing the probability and severity of rare but high-impact interruption events. This paper presents a risk-aware evaluation framework that couples year-scale BESS dispatch on a coarse time grid with a secondwise outage-event simulator capturing uninterruptible power supply (UPS) ride-through, multi-unit generator start uncertainty (delays and fail-to-start), ramp-limited pickup, and SOC-limited BESS support. Four dispatch policies are compared across 900 configurations and 288,000 simulated operating years: an oracle mixed-integer linear program (MILP) that co-optimizes energy charges, demand charges, and cycling penalties under a soft reserve penalty; a standby-only reserve-maintenance policy; a rule-based heuristic; and a learning-based surrogate (XGBoost) trained on oracle MILP labels with online feasibility projection. Reliability is quantified using distributional and tail-focused metrics including ECDF/CCDF diagnostics, service-level agreement (SLA) exceedance probability, conditional value-at-risk (CVaR), and event time-to-failure survival. Results show that the cost-optimal MILP policy systematically depletes ride-through reserves: across 337,200 outage events it enters outages at a median SOC of 0.05 (the hard floor), producing a per-outage failure rate of 0.726 and a CVaR95 downtime of 2.15 hr compared to 0.386 and 0.30 hr for reserve-preserving standby operation, which also achieves the lowest total cost under the evaluated demand-charge-heavy tariff. Policy dominance is fundamentally tail-dependent: policies with similar mean downtime exhibit up to $7\times $ differences in tail-conditional severity. The learning-based surrogate attains near-oracle cost fidelity ( $R^{2} = 0.9998$ ) at $3.8\times $ lower mean computation time with near-zero latency variance (50 ms $\pm ~1.7$ ms vs. 188 ms mean / 5.1 s worst-case for the MILP solver), but inherits the oracle’s reliability risk posture. Explicit operational guidance is provided for reliability-constrained, cost-constrained, and balanced operating regimes.

Zitieren

APA

Iqbal, H., & Sarwat, A. (2026). Risk-Aware Data Center BESS Dispatch With MILP, Machine Learning, and Stochastic Outage Simulations. IEEE Access, 14, 60593-60615. https://doi.org/10.1109/access.2026.3682635

Vancouver

Iqbal H, Sarwat A. Risk-Aware Data Center BESS Dispatch With MILP, Machine Learning, and Stochastic Outage Simulations. IEEE Access. 2026;14:60593-60615. doi:10.1109/access.2026.3682635

BibTeX
@article{Iqbal2026,
  author = {Iqbal, Hasan and Sarwat, Arif},
  title = {Risk-Aware Data Center BESS Dispatch With MILP, Machine Learning, and Stochastic Outage Simulations},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {60593--60615},
  doi = {10.1109/access.2026.3682635}
}
Kostenlos starten →