EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Decoupling Energy Stability and Thermal Response in Thermoelectric Atmospheric Water Generators

María C. Salgado-Gutiérrez, Jose L. Lopez-Moreno, Perla Y. Sevilla-Camacho, Gilbert F. Pérez-García, Rubén Martínez-Revuelta, Horacio I. Solis-Cisneros

IEEE Access · 2026 · 14 · 56938-56946

DOI: 10.1109/access.2026.3679556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von María C. Salgado-Gutiérrez und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mexico-SECIHTI Postgraduate Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The escalating global water scarcity has intensified the need for decentralized atmospheric water generation technologies. While thermoelectric cooling systems offer precise controllability, their operational reliability is frequently evaluated using static metrics that noverlook transient thermodynamic behaviors. Understanding dynamic reproducibility is crucial to ensuring consistent performance under real-world environmental fluctuations where thermal inertia can lead to significant drifts. This work experimentally evaluates the temporal consistency of a Peltier cell-based prototype operated under six distinct control strategies. Three independent trials were conducted per strategy, acquiring time-series data for cold-side temperature, energy consumption, and the thermal lift coefficient. Dynamic Time Warping was introduced as a robust metric to quantify morphological similarity and align non-linear deviations across experimental replicates, overcoming the limitations of rigid Euclidean metrics. Results reveal a significant dynamic decoupling between energy stability and thermal response. While electrical input remained highly reproducible with average distances below 1.15 Wh, thermal variables exhibited substantial dispersion. Specifically, the thermal lift coefficient reached distances up to 113.53, highlighting that stable energy profiles do not guarantee consistent thermodynamic behavior. Modified ON/OFF schemes amplified temporal instability, whereas proportional-integral and adaptive logic minimized structural dispersion. These findings demonstrate that time-averaged metrics are insufficient for characterizing thermoelectric systems under dynamic loads. The study establishes a non-invasive evaluation framework, providing a baseline for designing the next generation of robust, intelligent control architectures necessary for reliable atmospheric water generation deployment.

Förderung

  • Mexico-SECIHTI Postgraduate Program

Zitieren

APA

Salgado-Gutiérrez, M. C., Lopez-Moreno, J. L., Sevilla-Camacho, P. Y., Pérez-García, G. F., Martínez-Revuelta, R., & Solis-Cisneros, H. I. (2026). Decoupling Energy Stability and Thermal Response in Thermoelectric Atmospheric Water Generators. IEEE Access, 14, 56938-56946. https://doi.org/10.1109/access.2026.3679556

Vancouver

Salgado-Gutiérrez MC, Lopez-Moreno JL, Sevilla-Camacho PY, Pérez-García GF, Martínez-Revuelta R, Solis-Cisneros HI. Decoupling Energy Stability and Thermal Response in Thermoelectric Atmospheric Water Generators. IEEE Access. 2026;14:56938-56946. doi:10.1109/access.2026.3679556

BibTeX
@article{SalgadoGutirrez2026,
  author = {Salgado-Gutiérrez, María C. and Lopez-Moreno, Jose L. and Sevilla-Camacho, Perla Y. and Pérez-García, Gilbert F. and Martínez-Revuelta, Rubén and Solis-Cisneros, Horacio I.},
  title = {Decoupling Energy Stability and Thermal Response in Thermoelectric Atmospheric Water Generators},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {56938--56946},
  doi = {10.1109/access.2026.3679556}
}
Kostenlos starten →