EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

LPG Humidity Sensor With Carbonyl-Rich Graphene-Oxide Coating

João V. De Castro, Anne Caroline Fernandes, Nayton Claudinei Vicentini, Giovanni Romeu Carvalho, Cristiano Legnani, Alessandro Henrique De Lima, Renato L. Faraco, Felipe O. Barino, Marcus Vinicius P. De Souza, Jonas H. Osório, Jefferson E. Tsuchida, Ulysses R. C. Vitor und 3 weitere

IEEE Access · 2026 · 14 · 36092-36101

DOI: 10.1109/access.2026.3668462 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von João V. De Castro und 14 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we investigated the relative humidity (RH) sensor performance using long-period fiber gratings (LPG) covered with carbonyl-rich graphene oxide (CGO). The LPG was produced using the electric-arc-heating process on single-mode fiber (SMF-28). The CGO was synthesized utilizing changes in the Hummers technique, two oxidation processes, and extended oxidation periods. Furthermore, the humidity sensor was created by dip-coating the LPG active region of the fiber with CGO. As a result, we discovered that, when RH varies, the extremely hydrophilic CGO coating alters the effective refractive index of cladding modes. At room temperature (25°C), the sensor sensitivity was reported to be between 40% and 70% RH. High sensitivity (0.0153 dB/%RH), good linearity (99%), and minimal hysteresis in the measured range were obtained. Given these considerations and the fact that RH sensors based on LPG coated with CGO are inexpensive, compact in size, have no electromagnetic interference, are easily integrated into remote sensing, and can be easily fabricated on large scales, this new sensor may be a promising technology for RH sensing.

Förderung

  • Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior

Zitieren

APA

Castro, J. V. D., Fernandes, A. C., Vicentini, N. C., Carvalho, G. R., Legnani, C., Lima, A. H. D., Faraco, R. L., Barino, F. O., Souza, M. V. P. D., Osório, J. H., Tsuchida, J. E., Vitor, U. R. C., Coelho, D. V. N., Quirino, W. G., & Santos, A. B. D. (2026). LPG Humidity Sensor With Carbonyl-Rich Graphene-Oxide Coating. IEEE Access, 14, 36092-36101. https://doi.org/10.1109/access.2026.3668462

Vancouver

Castro JVD, Fernandes AC, Vicentini NC, Carvalho GR, Legnani C, Lima AHD, et al. LPG Humidity Sensor With Carbonyl-Rich Graphene-Oxide Coating. IEEE Access. 2026;14:36092-36101. doi:10.1109/access.2026.3668462

BibTeX
@article{Castro2026,
  author = {Castro, João V. De and Fernandes, Anne Caroline and Vicentini, Nayton Claudinei and Carvalho, Giovanni Romeu and Legnani, Cristiano and Lima, Alessandro Henrique De and Faraco, Renato L. and Barino, Felipe O. and Souza, Marcus Vinicius P. De and Osório, Jonas H. and Tsuchida, Jefferson E. and Vitor, Ulysses R. C. and Coelho, Diogo V. N. and Quirino, Welber G. and Santos, Alexandre Bessa Dos},
  title = {LPG Humidity Sensor With Carbonyl-Rich Graphene-Oxide Coating},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {36092--36101},
  doi = {10.1109/access.2026.3668462}
}
Kostenlos starten →