Inherent Third-Harmonic Circulating Current in Delta-CHB STATCOM: Analysis and Compensation

João Victor Guimarães França, Dayane Do Carmo Mendonça, Heverton Augusto Pereira, Yu Jin, Qian Xiao, Allan Fagner Cupertino

IEEE Access · 2025 · 13 · 110365-110378

DOI: 10.1109/access.2025.3582584 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2025. Verfasst von João Victor Guimarães França und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordination for the Improvement of Higher Education Personnel-CAPES, Conselho Nacional de Desenvolvimento Científico e Tecnológico-CNPq, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-CAPES.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Delta-connected Cascaded H-Bridge (Delta-CHB) is one of the most commonly adopted topologies for Static Synchronous Compensator (STATCOM) systems. Due to the oscillating instantaneous power resulting from the multiplication of sinusoidal voltage and current, a second-order harmonic arises in the Delta-CHB dc-link. In addition to increasing the required capacitance, it introduces a third-harmonic circulating current (THCC), increasing power losses and semiconductor stress. This paper analytically describes this phenomenon and compares two suppression strategies. The proposed model stands out for its simplicity and effectiveness in STATCOM applications, providing a straightforward approach to estimating both the circulating current and the capacitor voltage ripple, also accounting for their mutual influence. The capacitor voltage model exhibited errors lower than 4.5% compared to the simulation and lower than 6.9% compared to the experiment. Similarly, the circulating current model showed an error lower than 3.1% compared to the simulation and under 15% in the experiment. The first suppression strategy analyzed, which involves adding a resonant controller for the circulating current, was able to practically eliminate the circulating current. The second suppression strategy, based on normalization, reduced the circulating current by 30.27% in the experiment, demonstrating sensitivity to the measurement and control implementation delays.

Förderung

  • Coordination for the Improvement of Higher Education Personnel-CAPES
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico-CNPq
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-CAPES
  • Fundação de Amparo á Pesquisa de Minas Gerais (FAPEMIG) and Instituto Nacional de Ciência e Tecnologia em Energia Elétrica

Zitieren

APA

França, J. V. G., Mendonça, D. D. C., Pereira, H. A., Jin, Y., Xiao, Q., & Cupertino, A. F. (2025). Inherent Third-Harmonic Circulating Current in Delta-CHB STATCOM: Analysis and Compensation. IEEE Access, 13, 110365-110378. https://doi.org/10.1109/access.2025.3582584

Vancouver

França JVG, Mendonça DDC, Pereira HA, Jin Y, Xiao Q, Cupertino AF. Inherent Third-Harmonic Circulating Current in Delta-CHB STATCOM: Analysis and Compensation. IEEE Access. 2025;13:110365-110378. doi:10.1109/access.2025.3582584

BibTeX
@article{Frana2025,
  author = {França, João Victor Guimarães and Mendonça, Dayane Do Carmo and Pereira, Heverton Augusto and Jin, Yu and Xiao, Qian and Cupertino, Allan Fagner},
  title = {Inherent Third-Harmonic Circulating Current in Delta-CHB STATCOM: Analysis and Compensation},
  journal = {IEEE Access},
  year = {2025},
  volume = {13},
  pages = {110365--110378},
  doi = {10.1109/access.2025.3582584}
}
Kostenlos starten →