Two Independent Single-Loop Voltage Mode Control Method for 3-Level Buck Converter
IEEE Access · 2024 · 12 · 151382-151394
DOI: 10.1109/access.2024.3476409 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2024. Verfasst von June-Bong Jeong und 3 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Korea Institute of Energy Technology Evaluation and Planning (KETEP) Grant through the Korea Government Ministry of Trade, Industry and Energy (MOTIE), Samsung.
Abstract (Originalsprache)
Compared to a basic buck converter, the 3-level buck converter operates with the output inductor at twice the switching frequency. Additionally, the voltage across its flying capacitor contributes to reducing the slope of the inductor current. These factors can result in a reduction in the maximum output current ripple by up to four times, enabling the use of a smaller output inductor. Moreover, the voltage stress on the switches is only half of the input voltage. Therefore, the 3-level buck converter is advantageous for achieving high efficiency and high power density. To maintain these advantages, the voltage across the flying capacitor must be kept at half of the input voltage. Conventionally, this condition is usually ensured by using peak or valley current mode control methods. However, these methods have complex control circuits or algorithms and are vulnerable to noise interference because their operation is based on instantaneous peak or valley current sensing. Additionally, different control configurations must be employed for $M \lt 0.5$ and $M \gt 0.5$ , where M is the input-to-output voltage conversion ratio. In this paper, we propose a two independent single-loop voltage mode control method that can guarantee the flying capacitor voltage remains at half of the input voltage. The proposed control method is simple to implement and does not require current sensing or complex control algorithms, allowing the use of simple and low-cost digital or analog controllers. The method is also robust to noise interference because it only operates based on the output and flying capacitor voltage. Furthermore, this method ensures normal operation across all values of M without changing the control configuration. The experimental results from a 500 W-rated prototype confirmed the validity of the proposed control method.
Förderung
- Korea Institute of Energy Technology Evaluation and Planning (KETEP) Grant through the Korea Government Ministry of Trade, Industry and Energy (MOTIE)
- Samsung
Zitieren
APA
Jeong, J., Kim, C., Kang, J., & Han, S. (2024). Two Independent Single-Loop Voltage Mode Control Method for 3-Level Buck Converter. IEEE Access, 12, 151382-151394. https://doi.org/10.1109/access.2024.3476409
Vancouver
Jeong J, Kim C, Kang J, Han S. Two Independent Single-Loop Voltage Mode Control Method for 3-Level Buck Converter. IEEE Access. 2024;12:151382-151394. doi:10.1109/access.2024.3476409
BibTeX
@article{Jeong2024,
author = {Jeong, June-Bong and Kim, Chan-Gyu and Kang, Jeong-Il and Han, Sang-Kyoo},
title = {Two Independent Single-Loop Voltage Mode Control Method for 3-Level Buck Converter},
journal = {IEEE Access},
year = {2024},
volume = {12},
pages = {151382--151394},
doi = {10.1109/access.2024.3476409}
}
EUVIMED