Power Decoupling Enhancement of a Triple Active Bridge Converter With Feedforward Compensation Based on Model Predictive Control and Fuzzy Logic Controller in DC Microgrid Systems
IEEE Access · 2024 · 12 · 140310-140328
DOI: 10.1109/access.2024.3469815 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2024. Verfasst von Ahmed Hamed Ahmed Adam und 6 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Deanship of Graduate Studies and Scientific Research, Jouf University.
Abstract (Originalsprache)
DC microgrids, which use various energy sources, require an energy storage system (ESS) to stabilize the grid systems. Multiport active bridge (MAB) bidirectional DC-DC converters offer several advantages over other converters, including higher power density, bidirectional functionality, reduced component counts, soft switching ability, and a reduced number of conversion stages. However, these converters are affected by the cross-coupling effect of the control variable, with the power dissipated at each port significantly impacting the system response to step changes. This causes unstable DC bus voltage, slow dynamic response, large overshoot, and limits its reliability. To address this issue, a power decoupling with feedforward compensation based on model predictive control (MPC) and fuzzy compensation control (FCC) was developed. The proposed control strategy can achieve good transient performance (lower settling time, overshoot/undershoot in the controlled variables), excellent decoupling control performance, and high control flexibility with good precision to comply with DC voltage regulations. This article investigates the PD-MPC-FCC and its implementation in a triple active bridge (TAB) converter with multi-winding high-frequency transformers. The proposed MPC-FFC integrates MPC with fuzzy compensation control. The MPC aims to obtain more precise current reference values and implement current feedforward control to stabilize the DC bus voltage, while the FCC adaptively compensates for steady-state voltage errors. A hardware-in-the-loop (HIL) experimental case study using Typhoon 602 validates the TAB converter’s performance with the proposed PD-MPC-FCC strategy. Additionally, a comparison with previous works confirms the effectiveness of the proposed method. The HIL experimental setup and comparative analysis results demonstrate that the proposed method is effective, providing faster dynamic characteristics and port power decoupling operation capability.
Förderung
- Deanship of Graduate Studies and Scientific Research, Jouf University
Zitieren
APA
Adam, A. H. A., Chen, J., Xu, M., Kamel, S., Mustafa, G. I. Y., Zaki, Z. A., & Ahmed, E. M. (2024). Power Decoupling Enhancement of a Triple Active Bridge Converter With Feedforward Compensation Based on Model Predictive Control and Fuzzy Logic Controller in DC Microgrid Systems. IEEE Access, 12, 140310-140328. https://doi.org/10.1109/access.2024.3469815
Vancouver
Adam AHA, Chen J, Xu M, Kamel S, Mustafa GIY, Zaki ZA, et al. Power Decoupling Enhancement of a Triple Active Bridge Converter With Feedforward Compensation Based on Model Predictive Control and Fuzzy Logic Controller in DC Microgrid Systems. IEEE Access. 2024;12:140310-140328. doi:10.1109/access.2024.3469815
BibTeX
@article{Adam2024,
author = {Adam, Ahmed Hamed Ahmed and Chen, Jiawei and Xu, Minghan and Kamel, Salah and Mustafa, Ghazally I. Y. and Zaki, Zaki A. and Ahmed, Emad M.},
title = {Power Decoupling Enhancement of a Triple Active Bridge Converter With Feedforward Compensation Based on Model Predictive Control and Fuzzy Logic Controller in DC Microgrid Systems},
journal = {IEEE Access},
year = {2024},
volume = {12},
pages = {140310--140328},
doi = {10.1109/access.2024.3469815}
}
EUVIMED