Denoising Raman Spectra Using Autoencoder for Improved Analysis of Contamination in HDD
IEEE Access · 2024 · 12 · 113661-113676
DOI: 10.1109/access.2024.3441824 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2024. Verfasst von Sarun Gulyanon und 12 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Western Digital Storage Technologies (Thailand) Ltd..
Abstract (Originalsprache)
Small particles contaminated in hard disk drives (HDD) potentially cause damage to the device, leading to data loss. Hard disk industries, therefore, pay attention to identifying the types and sources of these contaminants. However, expensive analytical procedures are required for precise identification when testing samples are relatively small and scarce. A traditional tool, Raman spectroscopy, provides spectra with poor signal-to-noise ratios when dealing with sub-micron particles. Hence, human experts find noisy Raman spectral identification a real burden. In this study, we proposed a practically applicable pipeline, consisting of a denoising autoencoder with the spectral gradient correlation for the classification task, followed by the novel validation step based on an ensemble of CNN models to remove the predictions with low certainty. In the experiments, three different backbone models for denoising autoencoders are studied, including multilayer perceptron (MLP), convolutional neural network (CNN), and U-Net. While the ensemble model consists of eight different CNN models that act as independent machine experts whose votes indicate agreement with the correlation approach. When less agreement is observed, the sample is said to be unidentified and rejected from the classification task. With our validation step, the results bestow exceptionally high classification accuracy of 0.965, 0.955, and 0.976 for spectra undergoing our proposed pipeline with MLP, CNN, and U-Net autoencoder denoising models, respectively. This highlights the effectiveness of our proposed pipeline in practical application.
Förderung
- Western Digital Storage Technologies (Thailand) Ltd.
Zitieren
APA
Gulyanon, S., Deepaisarn, S., Chokphantavee, S., Chokphantavee, S., Prathipasen, P., Laitrakun, S., Opaprakasit, P., Viriyavit, W., Jaikaew, N., Jindakaew, J., Rakpongsiri, P., Meechamnan, T., & Sompongse, D. (2024). Denoising Raman Spectra Using Autoencoder for Improved Analysis of Contamination in HDD. IEEE Access, 12, 113661-113676. https://doi.org/10.1109/access.2024.3441824
Vancouver
Gulyanon S, Deepaisarn S, Chokphantavee S, Chokphantavee S, Prathipasen P, Laitrakun S, et al. Denoising Raman Spectra Using Autoencoder for Improved Analysis of Contamination in HDD. IEEE Access. 2024;12:113661-113676. doi:10.1109/access.2024.3441824
BibTeX
@article{Gulyanon2024,
author = {Gulyanon, Sarun and Deepaisarn, Somrudee and Chokphantavee, Sorawit and Chokphantavee, Sirawit and Prathipasen, Phuriphan and Laitrakun, Seksan and Opaprakasit, Pakorn and Viriyavit, Waranrach and Jaikaew, Narisara and Jindakaew, Jirawan and Rakpongsiri, Pornchai and Meechamnan, Thawanpat and Sompongse, Duangporn},
title = {Denoising Raman Spectra Using Autoencoder for Improved Analysis of Contamination in HDD},
journal = {IEEE Access},
year = {2024},
volume = {12},
pages = {113661--113676},
doi = {10.1109/access.2024.3441824}
}
EUVIMED