Fachartikel in der Zeitschrift IEEE Access, 2024. Verfasst von Muhammad Raza Khowja und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Next Generation High Lift System (NGHLS) Project, Collins Aerospace, Actuation Systems, U.K., Aerospace Technology Institute (ATI) Program, a joint government and industry investment to maintain and grow the U.K.’s competitive position in civil aerospac….
Abstract (Originalsprache)
This paper characterizes and develops life models for two different wire insulating materials: Poly-ether-ketone (PEEK) and nanofilled enamel (Allotherm wire). The article focuses on predicting the lifespan of PEEK and Allotherm wire insulating materials, specifically for use in low-voltage electrical machines. The study investigates the effects of thermal ageing in terms of dissipation factor, insulation capacitance, and partial discharge inception voltage (PDIV). Delamination of the insulation layer is observed in both wires during the ageing process, resulting in an increase in the differential dissipation factor and insulation capacitance. With respect to its unaged condition, Allotherm wire exhibits faster degradation, showing 2.4- and 4.5-times higher changes in the differential dissipation factor and insulation capacitance respectively compared to PEEK wire after the 16th ageing cycle. In addition, Allotherm wire experiences faster deterioration of the PDIV, with a 42% reduction compared to 32% in PEEK after the same ageing cycle. Using a single-stress Arrhenius life model, the study estimates the relative thermal index (RTI) for both materials as 245°C for PEEK and 226.25°C for Allotherm wire. These results indicate a 72.1% decrease in the lifetime of PEEK and a 25.5% decrease in the lifetime of Allotherm wire when compared to the manufacturer’s RTI specification.
Förderung
- Next Generation High Lift System (NGHLS) Project
- Collins Aerospace, Actuation Systems, U.K.
- Aerospace Technology Institute (ATI) Program, a joint government and industry investment to maintain and grow the U.K.’s competitive position in civil aerospac…
- Partnership Between the ATI, Department for Business, Energy and Industrial Strategy (BEIS) and Innovate U.K., addresses technology, capability, and supply cha…
Zitieren
APA
Khowja, M. R., Vakil, G., Ahmad, S. S., Ramanathan, R., Gerada, C., & Benarous, M. (2024). Life Characterization of PEEK and Nanofilled Enamel Insulated Wires Under Thermal Ageing. IEEE Access, 12, 39470-39483. https://doi.org/10.1109/access.2024.3374637
Vancouver
Khowja MR, Vakil G, Ahmad SS, Ramanathan R, Gerada C, Benarous M. Life Characterization of PEEK and Nanofilled Enamel Insulated Wires Under Thermal Ageing. IEEE Access. 2024;12:39470-39483. doi:10.1109/access.2024.3374637
BibTeX
@article{Khowja2024,
author = {Khowja, Muhammad Raza and Vakil, Gaurang and Ahmad, Syed Shahjahan and Ramanathan, Ramkumar and Gerada, Chris and Benarous, Maamar},
title = {Life Characterization of PEEK and Nanofilled Enamel Insulated Wires Under Thermal Ageing},
journal = {IEEE Access},
year = {2024},
volume = {12},
pages = {39470--39483},
doi = {10.1109/access.2024.3374637}
}
EUVIMED