EUVIMEDEUVIMED entdecken
Crossref

Parameter identification for MTPA control based on a nonlinear d-q dynamic IPMSM model

Mitja Garmut, Simon Steentjes, Martin Petrun

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering · 20.06.2023 · 42 (4) · 846-860

DOI: 10.1108/compel-09-2022-0331 ↗

Kurz gefasst

Fachartikel in der Zeitschrift COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, online erschienen am 12.12.2022. Verfasst von Mitja Garmut und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Small highly saturated interior permanent magnet- synchronous machines (IPMSMs) show a very nonlinear behaviour. Such machines are mostly controlled with a closed-loop cascade control, which is based on a d-q two-axis dynamic model with constant concentrated parameters to calculate the control parameters. This paper aims to present the identification of a complete current- and rotor position-dependent d-q dynamic model, which is derived by using a finite element method (FEM) simulation. The machine’s constant parameters are determined for an operation on the maximum torque per ampere (MTPA) curve. The obtained MTPA control performance was evaluated on the complete FEM-based nonlinear d-q model. Design/methodology/approach A FEM model was used to determine the nonlinear properties of the complete d-q dynamic model of the IPMSM. Furthermore, a fitting procedure based on the nonlinear MTPA curve is proposed to determine adequate constant parameters for MTPA operation of the IPMSM.

Findings

The current-dependent d-q dynamic model of the machine models the relevant dynamic behaviour of the complete current- and rotor position-dependent FEM-based d-q dynamic model. The most adequate control response was achieved while using the constant parameters fitted to the nonlinear MTPA curve by using the proposed method. Originality/value The effect on the motor’s steady-state and dynamic behaviour of differently complex d-q dynamic models was evaluated. A workflow to obtain constant set of parameters for the decoupled operation in the MTPA region was developed and their effect on the control response was analysed.

Zitieren

APA

Garmut, M., Steentjes, S., & Petrun, M. (2023). Parameter identification for MTPA control based on a nonlinear d-q dynamic IPMSM model. COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 42(4), 846-860. https://doi.org/10.1108/compel-09-2022-0331

Vancouver

Garmut M, Steentjes S, Petrun M. Parameter identification for MTPA control based on a nonlinear d-q dynamic IPMSM model. COMPEL - The international journal for computation and mathematics in electrical and electronic engineering. 2023;42(4):846-860. doi:10.1108/compel-09-2022-0331

BibTeX
@article{Garmut2023,
  author = {Garmut, Mitja and Steentjes, Simon and Petrun, Martin},
  title = {Parameter identification for MTPA control based on a nonlinear d-q dynamic IPMSM model},
  journal = {COMPEL - The international journal for computation and mathematics in electrical and electronic engineering},
  year = {2023},
  volume = {42},
  number = {4},
  pages = {846--860},
  doi = {10.1108/compel-09-2022-0331}
}
Kostenlos starten →