EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of electron-microscopy maps using solution small-angle X-ray scattering

Kristian Lytje, Jan Skov Pedersen iD

Acta Crystallographica Section D Structural Biology · 2024

DOI: 10.1107/s2059798324005497 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Acta Crystallographica Section D Structural Biology, 2024. Verfasst von Kristian Lytje und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, 8000 Aarhus, Denmark. Hauptthemen laut MEDLINE: Scattering, Small Angle, Cryoelectron Microscopy, Software, Models, Molecular. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Danmarks Frie Forskningsfond.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The determination of the atomic resolution structure of biomacromolecules is essential for understanding details of their function. Traditionally, such a structure determination has been performed with crystallographic or nuclear resonance methods, but during the last decade, cryogenic transmission electron microscopy (cryo-TEM) has become an equally important tool. As the blotting and flash-freezing of the samples can induce conformational changes, external validation tools are required to ensure that the vitrified samples are representative of the solution. Although many validation tools have already been developed, most of them rely on fully resolved atomic models, which prevents early screening of the cryo-TEM maps. Here, a novel and automated method for performing such a validation utilizing small-angle X-ray scattering measurements, publicly available through the new software package AUSAXS , is introduced and implemented. The method has been tested on both simulated and experimental data, where it was shown to work remarkably well as a validation tool. The method provides a dummy atomic model derived from the EM map which best represents the solution structure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Scattering, Small AngleCryoelectron MicroscopySoftwareModels, MolecularX-Ray DiffractionMicroscopy, Electron, Transmission

Stichwörter der Autor:innen

electron microscopyelectron-microscopy validationsmall-angle X-ray scatteringstructure determination

Autor:innen und Institutionen

  • Department of Chemistry and Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, 8000 Aarhus, Denmark.

ORCID-Profile: Jan Skov Pedersen

Förderung

  • Danmarks Frie Forskningsfond

Zitieren

APA

Lytje, K., & Pedersen, J. S. (2024). Validation of electron-microscopy maps using solution small-angle X-ray scattering. Acta Crystallographica Section D Structural Biology. https://doi.org/10.1107/s2059798324005497

Vancouver

Lytje K, Pedersen JS. Validation of electron-microscopy maps using solution small-angle X-ray scattering. Acta Crystallographica Section D Structural Biology. 2024. doi:10.1107/s2059798324005497

BibTeX
@article{Lytje2024,
  author = {Lytje, Kristian and Pedersen, Jan Skov},
  title = {Validation of electron-microscopy maps using solution small-angle X-ray scattering},
  journal = {Acta Crystallographica Section D Structural Biology},
  year = {2024},
  doi = {10.1107/s2059798324005497}
}
Kostenlos starten →