TAAM refinement on high-resolution experimental and simulated 3D ED/MicroED data for organic molecules

Anil Kumar iD, Kunal Kumar Jha iD, Barbara Olech, Tomasz Goral, Maura Malinska, Krzysztof Woźniak, Paulina Maria Dominiak iD

Acta Crystallographica Section C Structural Chemistry · 01.07.2024 · 80 (7) · 264-277

DOI: 10.1107/s2053229624005357 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Crystallographica Section C Structural Chemistry, online erschienen am 27.06.2024. Verfasst von Anil Kumar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biological and Chemical Research Centre, Faculty of Chemistry, University of Warsaw, ul. Żwirki i Wigury 101, 02-089 Warszawa, Poland. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Narodowe Centrum Nauki, the University of Warsaw supported by the Polish Ministry of Science and Higher Education, the Polish high-performance computing infrastructure PLGrid.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

3D electron diffraction (3D ED), or microcrystal electron diffraction (MicroED), has become an alternative technique for determining the high-resolution crystal structures of compounds from sub-micron-sized crystals. Here, we considered L-alanine, α-glycine and urea, which are known to form good-quality crystals, and collected high-resolution 3D ED data on our in-house TEM instrument. In this study, we present a comparison of independent atom model (IAM) and transferable aspherical atom model (TAAM) kinematical refinement against experimental and simulated data. TAAM refinement on both experimental and simulated data clearly improves the model fitting statistics ( R factors and residual electrostatic potential) compared to IAM refinement. This shows that TAAM better represents the experimental electrostatic potential of organic crystals than IAM. Furthermore, we compared the geometrical parameters and atomic displacement parameters (ADPs) resulting from the experimental refinements with the simulated refinements, with the periodic density functional theory (DFT) calculations and with published X-ray and neutron crystal structures. The TAAM refinements on the 3D ED data did not improve the accuracy of the bond lengths between the non-H atoms. The experimental 3D ED data provided more accurate H-atom positions than the IAM refinements on the X-ray diffraction data. The IAM refinements against 3D ED data had a tendency to lead to slightly longer X —H bond lengths than TAAM, but the difference was statistically insignificant. Atomic displacement parameters were too large by tens of percent for L-alanine and α-glycine. Most probably, other unmodelled effects were causing this behaviour, such as radiation damage or dynamical scattering.

Schlagwörter

Stichwörter der Autor:innen

3D EDIAMMicroEDTAAMelectron diffractionmicrocrystal

Autor:innen und Institutionen

  • Biological and Chemical Research Centre, Faculty of Chemistry, University of Warsaw, ul. Żwirki i Wigury 101, 02-089 Warszawa, Poland.
  • Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warszawa, Poland.
  • Centre of New Technologies, University of Warsaw, ul. S. Banacha 2c, 02-097 Warszawa, Poland.

ORCID-Profile: Anil Kumar, Kunal Kumar Jha, Paulina Maria Dominiak

Förderung

  • Narodowe Centrum Nauki
  • the University of Warsaw supported by the Polish Ministry of Science and Higher Education
  • the Polish high-performance computing infrastructure PLGrid

Zitieren

APA

Kumar, A., Jha, K. K., Olech, B., Goral, T., Malinska, M., Woźniak, K., & Dominiak, P. M. (2024). TAAM refinement on high-resolution experimental and simulated 3D ED/MicroED data for organic molecules. Acta Crystallographica Section C Structural Chemistry, 80(7), 264-277. https://doi.org/10.1107/s2053229624005357

Vancouver

Kumar A, Jha KK, Olech B, Goral T, Malinska M, Woźniak K, et al. TAAM refinement on high-resolution experimental and simulated 3D ED/MicroED data for organic molecules. Acta Crystallographica Section C Structural Chemistry. 2024;80(7):264-277. doi:10.1107/s2053229624005357

BibTeX
@article{Kumar2024,
  author = {Kumar, Anil and Jha, Kunal Kumar and Olech, Barbara and Goral, Tomasz and Malinska, Maura and Woźniak, Krzysztof and Dominiak, Paulina Maria},
  title = {TAAM refinement on high-resolution experimental and simulated 3D ED/MicroED data for organic molecules},
  journal = {Acta Crystallographica Section C Structural Chemistry},
  year = {2024},
  volume = {80},
  number = {7},
  pages = {264--277},
  doi = {10.1107/s2053229624005357}
}
Kostenlos starten →