Investigation of the milling characteristics of different focused-ion-beam sources assessed by three-dimensional electron diffraction from crystal lamellae
IUCrJ · 01.05.2023 · 10 (3) · 270-287
DOI: 10.1107/s2052252523001902 ↗Kurz gefasst
Fachartikel in der Zeitschrift IUCrJ, online erschienen am 24.03.2023. Verfasst von James M Parkhurst und 10 weiteren Autor:innen. Beteiligte Einrichtung: Rosalind Franklin Insititute, Harwell Science and Innovation Campus, Didcot, Oxford OX11 0QX, United Kingdom. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Medical Research Council.
Abstract (Originalsprache)
Three-dimensional electron diffraction (3DED) from nanocrystals of biological macromolecules requires the use of very small crystals. These are typically less than 300 nm-thick in the direction of the electron beam due to the strong interaction between electrons and matter. In recent years, focused-ion-beam (FIB) milling has been used in the preparation of thin samples for 3DED. These instruments typically use a gallium liquid metal ion source. Inductively coupled plasma (ICP) sources in principle offer faster milling rates. Little work has been done to quantify the damage these sources cause to delicate biological samples at cryogenic temperatures. Here, an analysis of the effect that milling with plasma FIB (pFIB) instrumentation has on lysozyme crystals is presented. This work evaluates both argon and xenon plasmas and compares them with crystals milled with a gallium source. A milling protocol was employed that utilizes an overtilt to produce wedge-shaped lamellae with a shallow thickness gradient which yielded very thin crystalline samples. 3DED data were then acquired and standard data-processing statistics were employed to assess the quality of the diffraction data. An upper bound to the depth of the pFIB-milling damage layer of between 42.5 and 50 nm is reported, corresponding to half the thickness of the thinnest lamellae that resulted in usable diffraction data. A lower bound of between 32.5 and 40 nm is also reported, based on a literature survey of the minimum amount of diffracting material required for 3DED.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Rosalind Franklin Insititute, Harwell Science and Innovation Campus, Didcot, Oxford OX11 0QX, United Kingdom.
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxford OX11 0QS, United Kingdom.
- Research Complex at Harwell, Harwell Science and Innovation Campus, Harwell, Oxford OX11 0FA, United Kingdom.
ORCID-Profile: Adam D Crawshaw, David Waterman, David I Stuart, James H Naismith, Gwyndaf Evans
Förderung
- Wellcome Trust
- Medical Research Council
Zitieren
APA
Parkhurst, J. M., Crawshaw, A. D., Siebert, C. A., Dumoux, M., Owen, C. D., Nunes, P., Waterman, D., Glen, T., Stuart, D. I., Naismith, J. H., & Evans, G. (2023). Investigation of the milling characteristics of different focused-ion-beam sources assessed by three-dimensional electron diffraction from crystal lamellae. IUCrJ, 10(3), 270-287. https://doi.org/10.1107/s2052252523001902
Vancouver
Parkhurst JM, Crawshaw AD, Siebert CA, Dumoux M, Owen CD, Nunes P, et al. Investigation of the milling characteristics of different focused-ion-beam sources assessed by three-dimensional electron diffraction from crystal lamellae. IUCrJ. 2023;10(3):270-287. doi:10.1107/s2052252523001902
BibTeX
@article{Parkhurst2023,
author = {Parkhurst, James M and Crawshaw, Adam D and Siebert, C Alistair and Dumoux, Maud and Owen, C David and Nunes, Pedro and Waterman, David and Glen, Thomas and Stuart, David I and Naismith, James H and Evans, Gwyndaf},
title = {Investigation of the milling characteristics of different focused-ion-beam sources assessed by three-dimensional electron diffraction from crystal lamellae},
journal = {IUCrJ},
year = {2023},
volume = {10},
number = {3},
pages = {270--287},
doi = {10.1107/s2052252523001902}
}
EUVIMED