Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 01.01.2027. Verfasst von Allison Peroutka und 8 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Science and Engineering Division, Argonne National Laboratory, Lemont, IL 60439, USA. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: US Department of Energy, Office of Science, European Synchrotron Radiation Facility.
Abstract (Originalsprache)
The recent availability of X-ray pixel-array detectors with nanosecond time resolution now allows X-ray photon correlation spectroscopy (XPCS) studies of nanosecond dynamics in materials. However, a storage-ring source of synchrotron radiation has temporal structure in the nanosecond domain which can contribute strongly to observed time correlation functions, especially for non-uniform fill patterns. When detectors can resolve them, such source effects extend out to tens of microseconds in typical XPCS analysis. Here it is shown how to characterize and remove the contribution from the source. Because the sample dynamics are uncorrelated with the source, the source time correlation function contributes simply as a multiplicative factor in the observed correlation function. Our results demonstrate that it is possible to measure the effect of source time structure from XPCS datasets and to remove it accurately, to reveal the dynamics of the sample into the nanosecond regime. Since non-uniform fill patterns are often used at storage-ring X-ray sources, this greatly extends the availability of beam time suitable for high-speed XPCS.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chemical Science and Engineering Division, Argonne National Laboratory, Lemont, IL 60439, USA.
- X-ray Science Division, Argonne National Laboratory, Lemont, IL 60439, USA.
- Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany.
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Quantum Optics and Quantum Information, Staudtstr. 1, 91058 Erlangen, Germany.
- ESRF - The European Synchrotron, Grenoble, France.
ORCID-Profile: Allison Peroutka, Dina Sheyfer, Jyotsana Lal, Jonathan Correa, Sebastian Karl, Yuriy Chushkin, Marco Cammarata, Michael Servis, Gregory B Stephenson
Förderung
- US Department of Energy, Office of Science
- European Synchrotron Radiation Facility
Zitieren
APA
Peroutka, A., Sheyfer, D., Lal, J., Correa, J., Karl, S., Chushkin, Y., Cammarata, M., Servis, M., & Stephenson, G. B. (2027). Effects of storage-ring time structure on high-speed X-ray photon correlation spectroscopy. Journal of Synchrotron Radiation, 34(1). https://doi.org/10.1107/s1600577526010441
Vancouver
Peroutka A, Sheyfer D, Lal J, Correa J, Karl S, Chushkin Y, et al. Effects of storage-ring time structure on high-speed X-ray photon correlation spectroscopy. Journal of Synchrotron Radiation. 2027;34(1). doi:10.1107/s1600577526010441
BibTeX
@article{Peroutka2027,
author = {Peroutka, Allison and Sheyfer, Dina and Lal, Jyotsana and Correa, Jonathan and Karl, Sebastian and Chushkin, Yuriy and Cammarata, Marco and Servis, Michael and Stephenson, Gregory B},
title = {Effects of storage-ring time structure on high-speed X-ray photon correlation spectroscopy},
journal = {Journal of Synchrotron Radiation},
year = {2027},
volume = {34},
number = {1},
doi = {10.1107/s1600577526010441}
}
EUVIMED