Total-reflection-based microscope compatible with X-ray and visible light for sample positioning
Journal of Synchrotron Radiation · 01.05.2026 · 33 (3) · 604-608
DOI: 10.1107/s1600577526003127 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 14.04.2026. Verfasst von Kyota Yoshinaga und 15 weiteren Autor:innen. Beteiligte Einrichtung: RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Science and Technology Agency, Japan Society for the Promotion of Science, Ministry of Education, Culture, Sports, Science and Technology.
Abstract (Originalsprache)
Sample positioning in X-ray imaging is often technically demanding and involves radiation exposure to the sample. For easier and damage-free positioning, the integration of a visible-light microscope is an effective and widely adopted approach. However, such visible-light microscopes require careful calibration of the objective optic against the X-ray microscope, which introduces additional challenges. To address this issue, we propose a simple total-reflection-based microscope compatible with X-rays and visible light using a Wolter mirror which functions as both X-ray condenser optic and visible-light objective optic. Calibrating our visible-light microscope requires only simple adjustment of an optical lens and three planar mirrors, while no adjustment of the objective optic. We constructed our proposed system for a soft X-ray ptychography system and successfully demonstrated the simple calibration of the visible-light microscope, which was then applied to position a biological sample without delivering a radiation dose.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan.
- The Institute for Solid State Physics, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581, Japan.
- Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan.
- Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan.
- Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan.
ORCID-Profile: Kyota Yoshinaga, Jordan Tyler O'Neal, Takenori Shimamura, Yasunori Senba, Taketoshi Kodama, Makina Yabashi, Haruhiko Ohashi, Takashi Kimura
Förderung
- Japan Science and Technology Agency
- Japan Society for the Promotion of Science
- Ministry of Education, Culture, Sports, Science and Technology
- Murata Science Foundation
- Japan Synchrotron Radiation Research Institute
- Precise Measurement Technology Promotion Foundation
- Asahi Group Foundation
- University of Tokyo
Zitieren
APA
Yoshinaga, K., O'Neal, J. T., Sakurai, K., Egawa, S., Furuya, N., Shimamura, T., Takeo, Y., Nakata, Y., Nagayama, Y., Kishimoto, H., Senba, Y., Shimura, M., Kodama, T., Yabashi, M., Ohashi, H., & Kimura, T. (2026). Total-reflection-based microscope compatible with X-ray and visible light for sample positioning. Journal of Synchrotron Radiation, 33(3), 604-608. https://doi.org/10.1107/s1600577526003127
Vancouver
Yoshinaga K, O'Neal JT, Sakurai K, Egawa S, Furuya N, Shimamura T, et al. Total-reflection-based microscope compatible with X-ray and visible light for sample positioning. Journal of Synchrotron Radiation. 2026;33(3):604-608. doi:10.1107/s1600577526003127
BibTeX
@article{Yoshinaga2026,
author = {Yoshinaga, Kyota and O'Neal, Jordan Tyler and Sakurai, Kai and Egawa, Satoru and Furuya, Noboru and Shimamura, Takenori and Takeo, Yoko and Nakata, Yu and Nagayama, Yuichi and Kishimoto, Hikaru and Senba, Yasunori and Shimura, Mari and Kodama, Taketoshi and Yabashi, Makina and Ohashi, Haruhiko and Kimura, Takashi},
title = {Total-reflection-based microscope compatible with X-ray and visible light for sample positioning},
journal = {Journal of Synchrotron Radiation},
year = {2026},
volume = {33},
number = {3},
pages = {604--608},
doi = {10.1107/s1600577526003127}
}
EUVIMED