Differential phase contrast for quantitative imaging and spectro-microscopy at a nanoprobe beamline
Journal of Synchrotron Radiation · 01.01.2023 · 30 (1) · 200-207
DOI: 10.1107/s1600577522010633 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 01.01.2023. Verfasst von Paul D Quinn und 5 weiteren Autor:innen. Beteiligte Einrichtung: Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The interaction of a focused X-ray beam with a sample in a scanning probe experiment can provide a variety of information about the interaction volume. In many scanning probe experiments X-ray fluorescence (XRF) is supplemented with measurements of the transmitted or scattered intensity using a pixelated detector. The automated extraction of different signals from an area pixelated detector is described, in particular the methodology for extracting differential phase contrast (DPC) is demonstrated and different processing methods are compared across a range of samples. The phase shift of the transmitted X-ray beam by the sample, extracted from DPC, is also compared with ptychography measurements to provide a qualitative and quantitative comparison. While ptychography produces a superior image, DPC can offer a simple, flexible method for phase contrast imaging which can provide fast results and feedback during an experiment; furthermore, for many science problems, such as registration of XRF in a lighter matrix, DPC can provide sufficient information to meet the experimental aims. As the DPC technique is a quantitative measurement, it can be expanded to spectroscopic studies and a demonstration of DPC for spectro-microscopy measurements is presented. Where ptychography can separate the absorption and phase shifts by the sample, quantitative interpretation of a DPC image or spectro-microscopy signal can only be performed directly when absorption is negligible or where the absorption contribution is known and the contributions can be fitted.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom.
ORCID-Profile: Paul D Quinn, Miguel A Gomez-Gonzalez, Julia E Parker
Zitieren
APA
Quinn, P. D., Cacho-Nerin, F., Gomez-Gonzalez, M. A., Parker, J. E., Poon, T., & Walker, J. M. (2023). Differential phase contrast for quantitative imaging and spectro-microscopy at a nanoprobe beamline. Journal of Synchrotron Radiation, 30(1), 200-207. https://doi.org/10.1107/s1600577522010633
Vancouver
Quinn PD, Cacho-Nerin F, Gomez-Gonzalez MA, Parker JE, Poon T, Walker JM. Differential phase contrast for quantitative imaging and spectro-microscopy at a nanoprobe beamline. Journal of Synchrotron Radiation. 2023;30(1):200-207. doi:10.1107/s1600577522010633
BibTeX
@article{Quinn2023,
author = {Quinn, Paul D and Cacho-Nerin, Fernando and Gomez-Gonzalez, Miguel A and Parker, Julia E and Poon, Timothy and Walker, Jessica M},
title = {Differential phase contrast for quantitative imaging and spectro-microscopy at a nanoprobe beamline},
journal = {Journal of Synchrotron Radiation},
year = {2023},
volume = {30},
number = {1},
pages = {200--207},
doi = {10.1107/s1600577522010633}
}