A reference material for X-ray diffraction line profile analysis
Journal of Applied Crystallography · 01.10.2025 · 58 (5) · 1764-1777
DOI: 10.1107/s1600576725006946 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Crystallography, online erschienen am 18.09.2025. Verfasst von P Scardi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Environmental and Mechanical Engineering University of Trento via Mesiano 77 38123Trento Italy. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Horizon 2020 Framework Programme, Ministero dell'Università e della Ricerca.
Abstract (Originalsprache)
A nanocrystalline Fe–1.8%Cr steel powder was tested as a reference material on more than five powder diffraction instruments and configurations, as well as with different data-analysis methodologies. The material, commercially available at low cost, was ground in a high-energy planetary mill to obtain homogeneous crystalline domain dimensions of 10 (2) nm, with size dispersion of 5 (1) nm and a nominal dislocation density of the order of 2.90 (2) × 10 16 m −2 . The powder is stable, easy to handle and suitable for preparing samples in any measurement geometry. It is well suited for testing the modelling of diffraction peak profiles, either individually or across the entire diffraction pattern, as in the Rietveld method. This paper reports the simple details for the production of the material and the analysis of the diffraction patterns collected with both laboratory and synchrotron beamline instruments, using X-rays of different energies. In particular, the screening of the data based on integral breadths (Williamson–Hall method), the analysis by whole powder pattern modelling and the analysis by the Rietveld method are shown. Aspects related to diffuse scattering and pair distribution function analysis are also discussed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Civil, Environmental and Mechanical Engineering University of Trento via Mesiano 77 38123Trento Italy.
- Momentum Transfer GmbH, Luruper Hauptstraße 1, 22547Hamburg, Germany.
- European Synchrotron Radiation Facility (ESRF) 71 Avenue des Martyrs 38000Grenoble France.
ORCID-Profile: P Scardi, B Hinrichsen, A N Fitch
Förderung
- European Commission, Horizon 2020 Framework Programme
- Ministero dell'Università e della Ricerca
Zitieren
APA
Scardi, P., D'Incau, M., Malagutti, M. A., Terban, M. W., Hinrichsen, B., & Fitch, A. N. (2025). A reference material for X-ray diffraction line profile analysis. Journal of Applied Crystallography, 58(5), 1764-1777. https://doi.org/10.1107/s1600576725006946
Vancouver
Scardi P, D'Incau M, Malagutti MA, Terban MW, Hinrichsen B, Fitch AN. A reference material for X-ray diffraction line profile analysis. Journal of Applied Crystallography. 2025;58(5):1764-1777. doi:10.1107/s1600576725006946
BibTeX
@article{Scardi2025,
author = {Scardi, P and D'Incau, M and Malagutti, M A and Terban, M W and Hinrichsen, B and Fitch, A N},
title = {A reference material for X-ray diffraction line profile analysis},
journal = {Journal of Applied Crystallography},
year = {2025},
volume = {58},
number = {5},
pages = {1764--1777},
doi = {10.1107/s1600576725006946}
}
EUVIMED