Frequency Stability of 2.5 × 10 − 17 from a Si Cavity with AlGaAs Crystalline Mirrors
Physical Review Letters · 20.01.2026 · 136 (3)
DOI: 10.1103/zgrm-cjbb ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review Letters, online erschienen am 20.01.2026. Verfasst von Dahyeon Lee und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of Colorado, JILA, National Institute of Standards and Technology and the University of Colorado, Boulder, Colorado 80309-0440, USA and De…. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 66 Literaturangaben. Gefördert von: National Science Foundation, Deutsche Forschungsgemeinschaft, NIST.
Abstract (Originalsprache)
Developments in ultrastable lasers have fueled remarkable advances in optical frequency metrology and quantum science. A key ingredient in further improving laser frequency stability is the use of low-noise mirror materials such as AlGaAs crystalline coatings. However, excess noise observed with these coatings limits the performance of cryogenic silicon cavities with AlGaAs mirrors to similar levels achieved with conventional dielectric coatings. With a new pair of crystalline coated mirrors in a 6-cm-long cryogenic silicon cavity operated at 17 K, we demonstrate a clear advantage of crystalline coatings over dielectric coatings. The achieved fractional frequency stability of 2.5×10^{-17} at 10 s is four times better than expected for dielectric mirrors and corresponds to more than a tenfold reduction in the coating mechanical loss factor. We also combine two silicon cavities to demonstrate optical frequency averaging for enhanced stability. In addition, we present a long-term frequency drift record of four cryogenic silicon cavities measured over several years. These results open up realistic prospects for cavity-stabilized lasers with 10^{-18} fractional stability, as well as an all-optical timescale with continuously operating optical local oscillators.
Autor:innen und Institutionen
- University of Colorado, JILA, National Institute of Standards and Technology and the University of Colorado, Boulder, Colorado 80309-0440, USA and Department of Physics, Boulder, Colorado 80309-0390, USA.
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany.
Förderung
- National Science Foundation
- Deutsche Forschungsgemeinschaft
- NIST
Zitieren
APA
Lee, D., Hu, Z. Z., Lewis, B., Aeppli, A., Kim, K., Yao, Z., Legero, T., Nicolodi, D., Riehle, F., Sterr, U., & Ye, J. (2026). Frequency Stability of 2.5 × 10 − 17 from a Si Cavity with AlGaAs Crystalline Mirrors. Physical Review Letters, 136(3). https://doi.org/10.1103/zgrm-cjbb
Vancouver
Lee D, Hu ZZ, Lewis B, Aeppli A, Kim K, Yao Z, et al. Frequency Stability of 2.5 × 10 − 17 from a Si Cavity with AlGaAs Crystalline Mirrors. Physical Review Letters. 2026;136(3). doi:10.1103/zgrm-cjbb
BibTeX
@article{Lee2026,
author = {Lee, Dahyeon and Hu, Zoey Z and Lewis, Ben and Aeppli, Alexander and Kim, Kyungtae and Yao, Zhibin and Legero, Thomas and Nicolodi, Daniele and Riehle, Fritz and Sterr, Uwe and Ye, Jun},
title = {Frequency Stability of 2.5 × 10 − 17 from a Si Cavity with AlGaAs Crystalline Mirrors},
journal = {Physical Review Letters},
year = {2026},
volume = {136},
number = {3},
doi = {10.1103/zgrm-cjbb}
}
EUVIMED