Isolated attosecond pulses generated from a relativistic plasma mirror via noncollinear gating
Physical Review Research · 27.02.2025 · 7 (1)
DOI: 10.1103/physrevresearch.7.013216 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review Research, online erschienen am 27.02.2025. Verfasst von Hyeon Kim und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute for Basic Science, National Research Foundation of Korea.
Abstract (Originalsprache)
A train of intense attosecond pulses can be obtained through relativistic high harmonic generation when an intense laser field is reflected on a plasma surface. Separating a single isolated attosecond pulse from the train is critical not only for applications such as time-resolved pump-probe experiments but also for studying laser-plasma interactions with attosecond temporal resolution. Various methods have been developed for an isolated attosecond pulse generation in gas. However, they require ultrashort laser pulses, which are difficult to apply with high-power lasers typically employed in relativistic high harmonic generation. Here, we demonstrate that an isolated attosecond pulse can be obtained through relativistic high harmonic generation using noncollinear temporal gating. Our approach also provides direct access to each attosecond pulse in the train, allowing us to diagnose the laser-plasma interaction, such as plasma denting and reflection positions, in a time-resolved manner. Thus, it offers breakthroughs in attosecond pulse generation at relativistic laser intensities.
Förderung
- Institute for Basic Science
- National Research Foundation of Korea
Zitieren
APA
Kim, H., Kim, C. M., Pae, K. H., & Kim, K. T. (2025). Isolated attosecond pulses generated from a relativistic plasma mirror via noncollinear gating. Physical Review Research, 7(1). https://doi.org/10.1103/physrevresearch.7.013216
Vancouver
Kim H, Kim CM, Pae KH, Kim KT. Isolated attosecond pulses generated from a relativistic plasma mirror via noncollinear gating. Physical Review Research. 2025;7(1). doi:10.1103/physrevresearch.7.013216
BibTeX
@article{Kim2025,
author = {Kim, Hyeon and Kim, Chul Min and Pae, Ki Hong and Kim, Kyung Taec},
title = {Isolated attosecond pulses generated from a relativistic plasma mirror via noncollinear gating},
journal = {Physical Review Research},
year = {2025},
volume = {7},
number = {1},
doi = {10.1103/physrevresearch.7.013216}
}
EUVIMED