Exceptional-Point Sensors Offer No Fundamental Signal-to-Noise Ratio Enhancement
Physical Review Letters · 13.06.2024 · 132 (24)
DOI: 10.1103/physrevlett.132.243601 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review Letters, online erschienen am 13.06.2024. Verfasst von Hudson Loughlin und 1 weiteren Autor:innen. Beteiligte Einrichtung: LIGO Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA. Die Arbeit wurde bisher 81-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Science Foundation.
Abstract (Originalsprache)
Exceptional-point (EP) sensors exhibit a square-root resonant frequency bifurcation in response to external perturbations, making them appear attractive for sensing applications. However, there is an open debate as to whether or not this sensitivity advantage is negated by additional noise in the system. We settle this debate by showing that increased fundamental noises of quantum and thermal origin in EP sensors, and in particular self-excited (or PT-symmetric) EP sensors, negate the sensitivity benefit. Accordingly, EP sensing schemes are only beneficial either with further quantum enhancement or if compared to sensors limited by technical noise. As many modern sensors are limited by technical noise, EP sensors may still find practical uses despite their lack of a fundamental advantage. Alternatively, we propose a quantum-enhanced EP sensor that achieves a sensing advantage even when limited by quantum or thermal fluctuations.
Autor:innen und Institutionen
- LIGO Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
Förderung
- National Science Foundation
Zitieren
APA
Loughlin, H., & Sudhir, V. (2024). Exceptional-Point Sensors Offer No Fundamental Signal-to-Noise Ratio Enhancement. Physical Review Letters, 132(24). https://doi.org/10.1103/physrevlett.132.243601
Vancouver
Loughlin H, Sudhir V. Exceptional-Point Sensors Offer No Fundamental Signal-to-Noise Ratio Enhancement. Physical Review Letters. 2024;132(24). doi:10.1103/physrevlett.132.243601
BibTeX
@article{Loughlin2024,
author = {Loughlin, Hudson and Sudhir, Vivishek},
title = {Exceptional-Point Sensors Offer No Fundamental Signal-to-Noise Ratio Enhancement},
journal = {Physical Review Letters},
year = {2024},
volume = {132},
number = {24},
doi = {10.1103/physrevlett.132.243601}
}
EUVIMED