We demonstrate a closed-loop light-pulse atom interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two 2D$^+$ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase-locking these interferometers via the Raman laser phases from the sum interferometer signal, and the gyroscope perfomance is improved. We achieve long-term stabilities of $6.1 \ \mu g$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87ms (interference area $A=0.097$ mm$^2$). This work provides a building block for an atomic interferometer based inertial measurement unit for use in field applications that require a high data-rate and high stability.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Meng, Z., Yan, P., Wang, S., Li, X., Xue, H., & Feng, Y. (2024). Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams. Physical Review Applied, 21(3). https://doi.org/10.1103/physrevapplied.21.034050

Vancouver

Meng Z, Yan P, Wang S, Li X, Xue H, Feng Y. Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams. Physical Review Applied. 2024;21(3). doi:10.1103/physrevapplied.21.034050

BibTeX
@article{Meng2024,
  author = {Meng, Zhi-Xin and Yan, Pei-Qiang and Wang, Sheng-Zhe and Li, Xiao-Jie and Xue, Hong-Bo and Feng, Yan-Ying},
  title = {Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams},
  journal = {Physical Review Applied},
  year = {2024},
  volume = {21},
  number = {3},
  doi = {10.1103/physrevapplied.21.034050}
}
Kostenlos starten →