EUVIMEDEUVIMED entdecken
Crossref

Pulsed dual-axis alkali-metal–noble-gas comagnetometer

J. Wang, J. Lee, H. Loughlin, M. Hedges, M. V. Romalis

Physical Review A · 08.05.2025 · 111 (5)

DOI: 10.1103/physreva.111.053103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Review A, online erschienen am 08.05.2025. Verfasst von J. Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Science Foundation, Simons Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Alkali-metal-noble-gas comagnetometers are precision probes well-suited for tests of fundamental physics and inertial rotation sensing, combining high sensitivity of the spin-exchange-relaxation free (SERF) magnetometers with inherent suppression of magnetic field noise. Past versions of the device utilizing continuous-wave optical pumping are sensitive to a single axis perpendicular to the plane spanned by the orthogonal pump and probe laser beams. These devices are susceptible to light shifts in the alkali atoms, and to power and beam pointing fluctuations of both the probe and pump lasers, the latter of which is a dominant source of $1/f$ noise. In this work, we model and implement an approach to alkali-metal-noble-gas comagnetometers using pulsed optical pumping. After each pump laser pulse, an off-resonance probe beam measures the precession of noble-gas-spins-coupled alkali spins via optical rotation in the dark, thus eliminating effects from pump laser light shift and power fluctuations. Performing non-linear fitting on the sinusoidal transient signal with a proper phase enables separate and simultaneous measurement of signals along two orthogonal axes in the plane perpendicular to the pump beam. Effects from beam pointing fluctuations of the probe beam in the pump-probe plane is fundamentally eliminated, and signal response to pump beam pointing fluctuations is suppressed by compensation from noble-gas nuclear spins.

Förderung

  • National Science Foundation
  • Simons Foundation

Zitieren

APA

Wang, J., Lee, J., Loughlin, H., Hedges, M., & Romalis, M. V. (2025). Pulsed dual-axis alkali-metal–noble-gas comagnetometer. Physical Review A, 111(5). https://doi.org/10.1103/physreva.111.053103

Vancouver

Wang J, Lee J, Loughlin H, Hedges M, Romalis MV. Pulsed dual-axis alkali-metal–noble-gas comagnetometer. Physical Review A. 2025;111(5). doi:10.1103/physreva.111.053103

BibTeX
@article{Wang2025,
  author = {Wang, J. and Lee, J. and Loughlin, H. and Hedges, M. and Romalis, M. V.},
  title = {Pulsed dual-axis alkali-metal–noble-gas comagnetometer},
  journal = {Physical Review A},
  year = {2025},
  volume = {111},
  number = {5},
  doi = {10.1103/physreva.111.053103}
}
Kostenlos starten →