EUVIMEDEUVIMED entdecken
Crossref

Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond

Takuya Isogawa, Yuichiro Matsuzaki, Junko Ishi-Hayase

Physical Review A · 29.06.2023 · 107 (6)

DOI: 10.1103/physreva.107.062423 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Review A, online erschienen am 29.06.2023. Verfasst von Takuya Isogawa und 2 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science, Japan Science and Technology Corporation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The measurement of vector magnetic fields with high sensitivity and spatial resolution is important for both fundamental science and engineering applications. In particular, magnetic-field sensing with nitrogen-vacancy (NV) centers in diamond is a promising approach that can outperform existing methods. Recent studies have demonstrated vector DC magnetic-field sensing with perfectly aligned NV centers, which showed a higher readout contrast than NV centers having four equally distributed orientations. However, to estimate the azimuthal angle of the target magnetic field with respect to the NV axis in these previous approaches, it is necessary to apply a strong reference DC magnetic field, which can perturb the system to be measured. This is a crucial problem, especially when attempting to measure vector magnetic fields from materials that are sensitive to applied DC magnetic fields. Here, we propose a method to measure vector DC magnetic fields using perfectly aligned NV centers without reference DC magnetic fields. More specifically, we used the direction of linearly polarized microwave fields to induce Rabi oscillation as a reference and estimated the azimuthal angle of the target fields from the Rabi frequency. We further demonstrate the potential of our method to improve sensitivity by using entangled states to overcome the standard quantum limit. Our method of using a reference microwave field is a novel technique for sensitive vector DC magnetic-field sensing.

Förderung

  • Ministry of Education, Culture, Sports, Science and Technology
  • Japan Society for the Promotion of Science
  • Japan Science and Technology Corporation

Zitieren

APA

Isogawa, T., Matsuzaki, Y., & Ishi-Hayase, J. (2023). Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond. Physical Review A, 107(6). https://doi.org/10.1103/physreva.107.062423

Vancouver

Isogawa T, Matsuzaki Y, Ishi-Hayase J. Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond. Physical Review A. 2023;107(6). doi:10.1103/physreva.107.062423

BibTeX
@article{Isogawa2023,
  author = {Isogawa, Takuya and Matsuzaki, Yuichiro and Ishi-Hayase, Junko},
  title = {Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond},
  journal = {Physical Review A},
  year = {2023},
  volume = {107},
  number = {6},
  doi = {10.1103/physreva.107.062423}
}