ANUBIS detector and its sensitivity to neutral long-lived particles
Physical Review D · 06.11.2026 · 114 (9)
DOI: 10.1103/kd5j-d4fv ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review D, online erschienen am 06.11.2026. Verfasst von Thomas Adolphus und 39 weiteren Autor:innen. Die Arbeit nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Long-lived particles (LLPs), i.e., particles with macroscopic lifetimes τ > 10 ps , appear in various extensions of the Standard Model (SM) that address fundamental questions like the particulate nature of dark matter or baryogenesis. The ANUBIS detector will achieve unprecedented sensitivity to such models compared to existing and approved experiments by instrumenting a large decay volume adjacent to the ATLAS experiment at the high-luminosity LHC with tracking detectors. This paper outlines the proposed detector layouts for ANUBIS, explores their physics potential with a scalar LLP model, and identifies the preferred layout, comparing it to other experiments. The potential background contributions are estimated using a data-driven method, and the topology of potential background events is studied using Monte Carlo simulations. Overall, the ANUBIS detector is expected to probe branching ratios down to O ( 10 − 6 ) for exotic decays of the Higgs boson to scalar long-lived particles with masses of 10, 15, 40, and 60 GeV and proper lifetimes of c τ = 2.4 , 3.0, 12, and 18 m, respectively. Moreover, for branching ratios of 0.1% of the Higgs boson into long-lived scalars with a mass of 15 GeV, the ANUBIS detector can probe a c τ range between 1.1 × 10 − 1 m and 4.0 × 10 3 m .
Zitieren
APA
Adolphus, T., Aielli, G., Akhtar, J., Atwal, A., Bauer, M., Bentham, R., Brandt, O., Burling, J., Burr, J., Collins, P., Corpe, L. D., Coxon, M., Dej, J., Erner, S. N., Ruiz, C. F., Jelinek, J., Kortner, O., Kroha, H., Lee, L., …, & Valentino, O. (2026). ANUBIS detector and its sensitivity to neutral long-lived particles. Physical Review D, 114(9). https://doi.org/10.1103/kd5j-d4fv
Vancouver
Adolphus T, Aielli G, Akhtar J, Atwal A, Bauer M, Bentham R, et al. ANUBIS detector and its sensitivity to neutral long-lived particles. Physical Review D. 2026;114(9). doi:10.1103/kd5j-d4fv
BibTeX
@article{Adolphus2026,
author = {Adolphus, Thomas and Aielli, Giulio and Akhtar, Jahanzeb and Atwal, Arun and Bauer, Martin and Bentham, Rachel and Brandt, Oleg and Burling, Jude and Burr, Jon and Collins, Patrick and Corpe, Louie Dartmoor and Coxon, Matthew and Dej, Jonas and Erner, Sofie Nordahl and Ruiz, Cayetano Fernandez and Jelinek, Jindrich and Kortner, Oliver and Kroha, Hubert and Lee, Lawrence and Lester, Christopher and Liang, Yingshan and Liu, Kaijia and Mullin, Anna and Ohm, Christian and Peng, David and Pizzimento, Luca and Pontecorvo, Ludovico and Proto, Giorgia and Reymermier, Théo and Revering, Michael and Ritz, Elisa and Satterthwaite, Thomas P. and Shah, Aashaq and Simsek, Sinem and Soyk, Daniel and Spencer, Tom and Swallow, Paul and Szepfalvi, Balint and Tarannum, Noshin and Valentino, Olivia},
title = {ANUBIS detector and its sensitivity to neutral long-lived particles},
journal = {Physical Review D},
year = {2026},
volume = {114},
number = {9},
doi = {10.1103/kd5j-d4fv}
}
EUVIMED