Sample-Half-Inserted Quantum Interferometer
Physical Review Letters · 12.12.2025 · 135 (24)
DOI: 10.1103/hldy-gmnn ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review Letters, online erschienen am 12.12.2025. Verfasst von Wei Li und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Normal University, Key Laboratory of Low-Dimensional Quantum Structures and Quantum Control of Ministry of Education, Department of Physics and…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Program of Hunan Province, National Science Foundation.
Abstract (Originalsprache)
Quantum technologies have been widely recognized as unprecedented opportunities for ultrahigh precision metrology. As a celebrated example in modern quantum optics, the Hong-Ou-Mandel (HOM) interferometer is well known for enabling temporal resolutions on the attosecond scale. However, the relatively low Fisher information per trial in ordinary HOM measurements typically necessitates tens of thousands of repetitions to achieve such precision. Here, we propose and demonstrate a sample-half-inserted HOM (SHOM) interferometer, which enhances the Fisher information by 5 orders of magnitude in a single interference event. By introducing an asymmetric photon-sample interaction, the SHOM configuration produces a distinctive dip-bump-dip interference structure, converting what was previously viewed as an artifact into a helpful metrological resource. Experimentally, we measured the optical path difference with an average precision of 4.09 nm (13.63 as) and an average accuracy of 1.22 nm (4.07 as) using O(10^{7}) photons. Our results establish SHOM interferometry as an efficient phase-insensitive approach, not only paving the way toward practical quantum-enhanced thickness measurement for transparent materials, but also serving as an elegant strategy to improve the performance of various quantum devices.
Autor:innen und Institutionen
- Hunan Normal University, Key Laboratory of Low-Dimensional Quantum Structures and Quantum Control of Ministry of Education, Department of Physics and Synergetic Innovation Center for Quantum Effects and Applications, Ch…
- Wuhan Institute of Technology, Hubei Key Laboratory of Optical Information and Pattern Recognition, Wuhan 430205, China.
- Louisiana State University, Quantum Photonics Laboratory, Department of Physics and Astronomy, Baton Rouge, Louisiana 70803, USA.
- Nanjing University, College of Engineering and Applied Sciences and National Laboratory of Solid State Microstructures, Nanjing 210023, China.
- Suzhou Campus of Nanjing University, Shishan Laboratory, Suzhou 215000, China.
- University of Electro-Communications, Chofu, Tokyo 182-8585, Japan.
Förderung
- National Key Research and Development Program of China
- Science and Technology Program of Hunan Province
- National Science Foundation
- National Natural Science Foundations of China
- Innovative Talents and Teams in Jiangsu
- Quantum Science and Technology-National Science and Technology Major Project
Zitieren
APA
Li, W., Xie, T., Luo, Y. H., Zheng, K., Peng, M., Yang, H., Ding, C., Yuan, C. Z., Magaña-Loaiza, O. S., Xia, K., Shimizu, R., Jing, H., You, C., & Jin, R. B. (2025). Sample-Half-Inserted Quantum Interferometer. Physical Review Letters, 135(24). https://doi.org/10.1103/hldy-gmnn
Vancouver
Li W, Xie T, Luo YH, Zheng K, Peng M, Yang H, et al. Sample-Half-Inserted Quantum Interferometer. Physical Review Letters. 2025;135(24). doi:10.1103/hldy-gmnn
BibTeX
@article{Li2025,
author = {Li, Wei and Xie, Tao and Luo, Yu-Hang and Zheng, Kang and Peng, Meiyu and Yang, Hui and Ding, Chunling and Yuan, Chen-Zhi and Magaña-Loaiza, Omar S and Xia, Keyu and Shimizu, Ryosuke and Jing, Hui and You, Chenglong and Jin, Rui-Bo},
title = {Sample-Half-Inserted Quantum Interferometer},
journal = {Physical Review Letters},
year = {2025},
volume = {135},
number = {24},
doi = {10.1103/hldy-gmnn}
}
EUVIMED