Quantification of parasitic etalons in Fabry-Perot cavities and the errors they cause in Pound-Drever-Hall frequency stabilization schemes
Physical Review A · 27.07.2026 · 114 (1)
DOI: 10.1103/c99v-lj3d ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review A, online erschienen am 27.07.2026. Verfasst von Malte Misfeldt und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Aeronautics and Space Administration, Jet Propulsion Laboratory, Australian Research Council.
Abstract (Originalsprache)
The Pound-Drever-Hall (PDH) scheme is a well-known technique for stabilizing a laser's frequency to a reference length such as an optical cavity. However, if a PDH setup is not carefully designed, one might easily create parasitic etalons, which are caused by back reflections in the optical path. These etalons alter the electric fields being read out and, therefore, decrease the PDH performance. In this paper, we describe these etalons as the amplitude modulation of the nominal PDH signals and identify two different kinds of etalons: internal ones formed within a plane-parallel window and free-space etalons between two interfaces of different optical components. We experimentally probe these two etalons and verify our theory. Furthermore, we employ a dual-modulation scheme that is capable of measuring the optical cavity's Free Spectral Range and discuss the influence of these additional G Hz sidebands on the etalons. We conduct this study in the framework of future space-based interferometric laser ranging instruments in DLR/NASA's GRACE-Continuity and ESA's Next-Generation Gravity Mission.
Förderung
- National Aeronautics and Space Administration
- Jet Propulsion Laboratory
- Australian Research Council
- Australian Government
Zitieren
APA
Misfeldt, M., Rees, E. R., Wade, A., Rabeling, D., & McKenzie, K. (2026). Quantification of parasitic etalons in Fabry-Perot cavities and the errors they cause in Pound-Drever-Hall frequency stabilization schemes. Physical Review A, 114(1). https://doi.org/10.1103/c99v-lj3d
Vancouver
Misfeldt M, Rees ER, Wade A, Rabeling D, McKenzie K. Quantification of parasitic etalons in Fabry-Perot cavities and the errors they cause in Pound-Drever-Hall frequency stabilization schemes. Physical Review A. 2026;114(1). doi:10.1103/c99v-lj3d
BibTeX
@article{Misfeldt2026,
author = {Misfeldt, Malte and Rees, Emily Rose and Wade, Andrew and Rabeling, David and McKenzie, Kirk},
title = {Quantification of parasitic etalons in Fabry-Perot cavities and the errors they cause in Pound-Drever-Hall frequency stabilization schemes},
journal = {Physical Review A},
year = {2026},
volume = {114},
number = {1},
doi = {10.1103/c99v-lj3d}
}
EUVIMED