EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

First beam demonstration of a conduction-cooled Nb 3 Sn superconducting rf photoinjector

Chunguang Jing, Roman Kostin, Yubin Zhao, Pavel Avrakhov, Ernie Knight, Sam Posen, Grigory Eremeev, Timergali Khabiboulline, Damon Bice, Alexander Netepenko, Gongxiaohui Chen, Wanming Liu und 5 weitere

Physical Review Accelerators and Beams · 12.11.2026 · 29 (11)

DOI: 10.1103/bgwr-36wy ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Review Accelerators and Beams, online erschienen am 12.11.2026. Verfasst von Chunguang Jing und 16 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fermi Forward Discovery Group, LLC, DOE SBIR program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We report on the first beam produced by the world’s first conduction-cooled superconducting radio frequency (srf) photogun. Over the past 5 years, Euclid, working in collaboration with Fermilab and Argonne National Laboratory, has been developing a continuous-wave (cw), 1.5-cell, MeV-scale, conduction-cooled srf photogun operating at 1.3 GHz. The primary objective of this effort is to demonstrate ultrastable electron beams for ultrafast electron microscopy/diffraction (UEM/UED) applications, enabled by the exceptional shot-to-shot stability achievable with srf technology compared to room-temperature rf photoguns. Although srf systems were historically too costly for industrial deployment, two recent advancements: Nb 3 Sn coatings and conduction cooling, have dramatically reduced system complexity and operating costs. This srf photogun is designed to deliver true cw rf operation while dissipating only ∼ 2 W of rf power, eliminating the need for a high-power rf system and significantly reducing facility footprint. This srf photogun also features a raised Nb 3 Sn backwall serving as the photocathode, removing the need for an external cathode insert. cw rf operation with limited repetitive beam has been demonstrated. In this paper, we present the first beam results from this system along with its cooldown performance, Q -slope behavior, synchronization characteristics, and initial beam parameters.

Förderung

  • Fermi Forward Discovery Group, LLC
  • DOE SBIR program

Zitieren

APA

Jing, C., Kostin, R., Zhao, Y., Avrakhov, P., Knight, E., Posen, S., Eremeev, G., Khabiboulline, T., Bice, D., Netepenko, A., Chen, G., Liu, W., Wisniewski, E., Doran, S., Power, J., Reid, T., & Kelly, M. (2026). First beam demonstration of a conduction-cooled Nb 3 Sn superconducting rf photoinjector. Physical Review Accelerators and Beams, 29(11). https://doi.org/10.1103/bgwr-36wy

Vancouver

Jing C, Kostin R, Zhao Y, Avrakhov P, Knight E, Posen S, et al. First beam demonstration of a conduction-cooled Nb 3 Sn superconducting rf photoinjector. Physical Review Accelerators and Beams. 2026;29(11). doi:10.1103/bgwr-36wy

BibTeX
@article{Jing2026,
  author = {Jing, Chunguang and Kostin, Roman and Zhao, Yubin and Avrakhov, Pavel and Knight, Ernie and Posen, Sam and Eremeev, Grigory and Khabiboulline, Timergali and Bice, Damon and Netepenko, Alexander and Chen, Gongxiaohui and Liu, Wanming and Wisniewski, Eric and Doran, Scott and Power, John and Reid, Tom and Kelly, Michael},
  title = {First beam demonstration of a conduction-cooled Nb 3 Sn superconducting rf photoinjector},
  journal = {Physical Review Accelerators and Beams},
  year = {2026},
  volume = {29},
  number = {11},
  doi = {10.1103/bgwr-36wy}
}
Kostenlos starten →