Dead-zone-free orientation-based pulsed atomic magnetometer
Physical Review Research · 29.04.2026 · 8 (2)
DOI: 10.1103/3t3d-s3kx ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review Research, online erschienen am 29.04.2026. Verfasst von Jinghong Xu und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Quantum Science and Technology, Major Project of Smart Grid.
Abstract (Originalsprache)
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
Förderung
- National Natural Science Foundation of China
- Quantum Science and Technology
- Major Project of Smart Grid
Zitieren
APA
Xu, J., Jiang, L., Zou, Y., Li, X., Tian, H., Tian, W., Fang, C., Chen, Y., & Liu, J. (2026). Dead-zone-free orientation-based pulsed atomic magnetometer. Physical Review Research, 8(2). https://doi.org/10.1103/3t3d-s3kx
Vancouver
Xu J, Jiang L, Zou Y, Li X, Tian H, Tian W, et al. Dead-zone-free orientation-based pulsed atomic magnetometer. Physical Review Research. 2026;8(2). doi:10.1103/3t3d-s3kx
BibTeX
@article{Xu2026,
author = {Xu, Jinghong and Jiang, Liwei and Zou, Yuntian and Li, Xu and Tian, Haowen and Tian, Wenjing and Fang, Chi and Chen, Yuanqiang and Liu, Jiali},
title = {Dead-zone-free orientation-based pulsed atomic magnetometer},
journal = {Physical Review Research},
year = {2026},
volume = {8},
number = {2},
doi = {10.1103/3t3d-s3kx}
}
EUVIMED