EUVIMEDEUVIMED entdecken
Open Access

Batch correction methods used in single-cell RNA sequencing analyses are often poorly calibrated

Sindri Emmanúel Antonsson iD, Páll Melsted iD

Genome Research · 2025-08 · 35 (8) · 1832-1841

DOI: 10.1101/gr.279886.124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Genome Research, online erschienen am 07.07.2025. Verfasst von Sindri Emmanúel Antonsson und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Industrial Engineering, Mechanical Engineering, and Computer Science, University of Iceland, 102 Reykjavík, Iceland. Hauptthemen laut MEDLINE: Single-Cell Analysis, Sequence Analysis, RNA, RNA-Seq. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: University of Iceland Doctoral Grants and the Icelandic Research Fund Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the number of experiments that employ single-cell RNA sequencing (scRNA-seq) grows, it opens up the possibility of combining results across experiments or processing cells from the same experiment assayed in separate sequencing runs. The gain in the number of cells that can be compared comes at the cost of batch effects that may be present. Several methods have been proposed to combat this for scRNA-seq data sets. We compare eight widely used methods used for batch correction of scRNA-seq data sets. We present a novel approach to measure the degree to which the methods alter the data in the process of batch correction, both at the fine scale, comparing distances between cells, as well as measuring effects observed across clusters of cells. We demonstrate that many of the published methods are poorly calibrated in the sense that the process of correction creates measurable artifacts in the data. In particular, MNN, SCVI, and LIGER perform poorly in our tests, often altering the data considerably. Batch correction with Combat, ComBat-seq, BBKNN, and Seurat introduces artifacts that could be detected in our setup. However, we find that Harmony is the only method that consistently performs well in all the testing methodology we present. Therefore, Harmony is the only method we recommend using when performing batch correction of scRNA-seq data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Single-Cell AnalysisSequence Analysis, RNARNA-SeqHumansCalibrationArtifactsAlgorithms

Autor:innen und Institutionen

  • Faculty of Industrial Engineering, Mechanical Engineering, and Computer Science, University of Iceland, 102 Reykjavík, Iceland.
  • Faculty of Industrial Engineering, Mechanical Engineering, and Computer Science, University of Iceland, 102 Reykjavík, Iceland pmelsted@hi.is.

ORCID-Profile: Sindri Emmanúel Antonsson, Páll Melsted

Förderung

  • University of Iceland Doctoral Grants and the Icelandic Research Fund Project

Zitieren

APA

Antonsson, S. E., & Melsted, P. (2025). Batch correction methods used in single-cell RNA sequencing analyses are often poorly calibrated. Genome Research, 35(8), 1832-1841. https://doi.org/10.1101/gr.279886.124

Vancouver

Antonsson SE, Melsted P. Batch correction methods used in single-cell RNA sequencing analyses are often poorly calibrated. Genome Research. 2025;35(8):1832-1841. doi:10.1101/gr.279886.124

BibTeX
@article{Antonsson2025,
  author = {Antonsson, Sindri Emmanúel and Melsted, Páll},
  title = {Batch correction methods used in single-cell RNA sequencing analyses are often poorly calibrated},
  journal = {Genome Research},
  year = {2025},
  volume = {35},
  number = {8},
  pages = {1832--1841},
  doi = {10.1101/gr.279886.124}
}
Kostenlos starten →