Fachartikel in der Zeitschrift Microbiology, 2024. Verfasst von Zina Alfahl und 9 weiteren Autor:innen. Beteiligte Einrichtung: Antimicrobial Resistance and Microbial Ecology Group, School of Medicine, University of Galway, Galway, Ireland. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Shiga-Toxigenic Escherichia coli, Water Microbiology. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Environmental Protection Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Shiga toxin-producing Escherichia coli (STEC) is an important waterborne pathogen capable of causing serious gastrointestinal infections with potentially fatal complications, including haemolytic–uremic syndrome. All STEC serogroups harbour genes that encode at least one Shiga toxin ( stx1 and/or stx2 ), which constitute the primary virulence factors of STEC. Loop-mediated isothermal amplification (LAMP) enables rapid real-time pathogen detection with a high degree of specificity and sensitivity. The aim of this study was to develop and validate an on-site portable diagnostics workstation employing LAMP technology to permit rapid real-time STEC detection in environmental water samples. Water samples ( n =28) were collected from groundwater wells ( n =13), rivers ( n =12), a turlough ( n =2) and an agricultural drain ( n =1) from the Corrib catchment in Galway. Water samples (100 ml) were passed through a 0.22 µm filter, and buffer was added to elute captured cells. Following filtration, eluates were tested directly using LAMP assays targeting stx1 , stx2 and E. coli phoA genes. The portable diagnostics workstation was used in field studies to demonstrate the on-site testing capabilities of the instrument. Real-time PCR assays targeting stx1 and stx2 genes were used to confirm the results. The limit of detection for stx1 , stx2 and phoA LAMP assays were 2, 2 and 6 copies, respectively. Overall, stx1 , stx2 and phoA genes were detected by LAMP in 15/28 (53.6 %), 9/28 (32.2 %) and 24/28 (85.7 %) samples, respectively. For confirmation, the LAMP results for stx1 and stx2 correlated perfectly (100 %) with those obtained using PCR. The portable diagnostics workstation exhibited high sensitivity throughout the on-site operation, and the average time from sample collection to final result was 40 min. We describe a simple, transferable and efficient diagnostic technology for on-site molecular analysis of various water sources. This method allows on-site testing of drinking water, enabling evidence-based decision-making by public health and water management authorities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesShiga-Toxigenic Escherichia coliWater MicrobiologyMolecular Diagnostic TechniquesSensitivity and SpecificityRiversShiga Toxin 1Groundwater

Stichwörter der Autor:innen

E. coliLAMPSTECtestingtoxinswater contamination

Substanzen

Shiga Toxin 1

Autor:innen und Institutionen

  • Antimicrobial Resistance and Microbial Ecology Group, School of Medicine, University of Galway, Galway, Ireland.
  • Centre for One Health, Ryan Institute, University of Galway, Galway, Ireland.
  • Molecular Diagnostics Research Group, College of Science and Engineering, University of Galway, Galway, Ireland.
  • School of Biological, Earth and Environmental Sciences, University College Cork, Cork, Ireland.
  • Irish Centre for Research in Applied Geosciences (iCRAG), University College Dublin, Dublin, Ireland.
  • Environmental Sustainability and Health Institute, Technological University Dublin, Dublin, Ireland.

Förderung

  • Environmental Protection Agency

Zitieren

APA

Alfahl, Z., Biggins, S., Higgins, O., Chueiri, A., Smith, T. J., Morris, D., O'Dwyer, J., Hynds, P. D., Burke, L. P., & O'Connor, L. (2024). A rapid on-site loop-mediated isothermal amplification technology as an early warning system for the detection of Shiga toxin-producing Escherichia coli in water. Microbiology. https://doi.org/10.1099/mic.0.001485

Vancouver

Alfahl Z, Biggins S, Higgins O, Chueiri A, Smith TJ, Morris D, et al. A rapid on-site loop-mediated isothermal amplification technology as an early warning system for the detection of Shiga toxin-producing Escherichia coli in water. Microbiology. 2024. doi:10.1099/mic.0.001485

BibTeX
@article{Alfahl2024,
  author = {Alfahl, Zina and Biggins, Sean and Higgins, Owen and Chueiri, Alexandra and Smith, Terry J and Morris, Dearbháile and O'Dwyer, Jean and Hynds, Paul D and Burke, Liam P and O'Connor, Louise},
  title = {A rapid on-site loop-mediated isothermal amplification technology as an early warning system for the detection of Shiga toxin-producing Escherichia coli in water},
  journal = {Microbiology},
  year = {2024},
  doi = {10.1099/mic.0.001485}
}
Kostenlos starten →