EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The impact of agar depth on antimicrobial susceptibility testing by disc diffusion

Ioana D Olaru, Sarah Schoeler, Frieder Schaumburg

Journal of Medical Microbiology · 18.09.2024 · 73 (9)

DOI: 10.1099/jmm.0.001890 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Microbiology, erschienen am 18.09.2024. Verfasst von Ioana D Olaru und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Microbiology, University Hospital Münster, Münster, Germany. Hauptthemen laut MEDLINE: Agar, Anti-Bacterial Agents, Pseudomonas aeruginosa. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institutional Funds of the University Hospital Münster.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The European Committee on Antimicrobial Susceptibility Testing (EUCAST) specifies the agar depth (4±0.5 mm) when performing antimicrobial susceptibility testing (AST). Since the infrastructure to produce standardized agar may be lacking in settings with limited resources, we wanted to examine to what extent variation in agar depth affects the inhibition zone diameters of quality control (QC) strains and AST of clinical isolates.

Methods

The inhibition zone diameters on Mueller–Hinton II agar with different depths (2–6 mm) were tested for various QC strain–antimicrobial agent combinations using Escherichia coli ATCC 25922, Pseudomonas aeruginosa ATCC 27853 and Staphylococcus aureus ATCC 29213. The relationship between zone diameters at different agar depths and MICs was investigated for 35 clinical isolates ( E. coli , Klebsiella pneumoniae , S. aureus and P. aeruginosa ) from Sierra Leone using MICs as the reference.

Results

The inhibition zone diameters were within the acceptance ranges as defined by the EUCAST for the majority of QC strains and antimicrobials, independent of the agar depth. At extreme agar depths, inhibition zones were more frequently out of range. The accuracy of AST varied for clinical isolates at different agar depths for categorical agreement (85.8–94.6%), major error rate (0.4–2.1%) and very major error rate (VME: 3.3–12.5%).

Conclusions

Even if the QC strains were in the acceptance range at different agar depths, this does not rule out unacceptably high VME rates (>3%) in clinical isolates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AgarAnti-Bacterial AgentsPseudomonas aeruginosaHumansEscherichia coliMicrobial Sensitivity TestsStaphylococcus aureusCulture MediaDisk Diffusion Antimicrobial TestsKlebsiella pneumoniae

Stichwörter der Autor:innen

ASTantimicrobial susceptibility testingdisc diffusion

Substanzen

AgarAnti-Bacterial AgentsCulture Media

Autor:innen und Institutionen

  • Institute of Medical Microbiology, University Hospital Münster, Münster, Germany.

Förderung

  • Institutional Funds of the University Hospital Münster

Zitieren

APA

Olaru, I. D., Schoeler, S., & Schaumburg, F. (2024). The impact of agar depth on antimicrobial susceptibility testing by disc diffusion. Journal of Medical Microbiology, 73(9). https://doi.org/10.1099/jmm.0.001890

Vancouver

Olaru ID, Schoeler S, Schaumburg F. The impact of agar depth on antimicrobial susceptibility testing by disc diffusion. Journal of Medical Microbiology. 2024;73(9). doi:10.1099/jmm.0.001890

BibTeX
@article{Olaru2024,
  author = {Olaru, Ioana D and Schoeler, Sarah and Schaumburg, Frieder},
  title = {The impact of agar depth on antimicrobial susceptibility testing by disc diffusion},
  journal = {Journal of Medical Microbiology},
  year = {2024},
  volume = {73},
  number = {9},
  doi = {10.1099/jmm.0.001890}
}
Kostenlos starten →