EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants

Michelo Simuyandi, Kalo Musukuma, Tom Lonergan, Masuzyo Chirwa-Chobe, Masiliso Munyinda, Seke Muzazu, Sarah L. Caddy

Journal of General Virology · 12.11.2026 · 107 (11)

DOI: 10.1099/jgv.0.002379 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of General Virology, erschienen am 12.11.2026. Verfasst von Michelo Simuyandi und 6 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bill and Melinda Gates Foundation, Cornell University, Wellcome Trust.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotavirus remains a leading cause of severe childhood gastroenteritis worldwide, yet the immune correlates of protection have been challenging to define. Here, we present an updated, high-throughput fluorescent imaging-based assay to quantify neutralization of rotavirus by antibodies prior to virus entry into cells. This methodology enables sensitive and reproducible assessment of rotavirus-specific antibody function in clinical samples within 24 h. By coupling fluorescent-focus detection after a single round of viral replication with automated multi-channel high-content imaging and cell-counting pipelines, this methodology significantly increases throughput, accuracy and cellular quality control compared to traditional neutralizing ELISAs (nELISAs). We also verified that widely accessible fluorescent ELISpot plate readers can accurately quantify fluorescent foci, expanding the potential availability of this methodology. We validated the technical performance and practical utility of this assay using 142 archived serum samples from a clinical trial cohort of Zambian infants vaccinated with either oral Rotarix (G1P[8]) or a parenteral non-replicating rotavirus vaccine candidate. The automated fluorescent-focus readout demonstrated high reproducibility ( R 2 §amp;gt; 0.90 ), extended dynamic range and strong comparability to standard nELISA outputs. Parallel evaluations against serum IgA titres confirmed that high-throughput neutralization measurements capture functional antibody dynamics distinct from total binding IgA. This highlights the assay’s value as a robust tool for comprehensive immunogenicity profiling and vaccine candidate evaluation.

Förderung

  • Bill and Melinda Gates Foundation
  • Cornell University
  • Wellcome Trust

Zitieren

APA

Simuyandi, M., Musukuma, K., Lonergan, T., Chirwa-Chobe, M., Munyinda, M., Muzazu, S., & Caddy, S. L. (2026). A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants. Journal of General Virology, 107(11). https://doi.org/10.1099/jgv.0.002379

Vancouver

Simuyandi M, Musukuma K, Lonergan T, Chirwa-Chobe M, Munyinda M, Muzazu S, et al. A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants. Journal of General Virology. 2026;107(11). doi:10.1099/jgv.0.002379

BibTeX
@article{Simuyandi2026,
  author = {Simuyandi, Michelo and Musukuma, Kalo and Lonergan, Tom and Chirwa-Chobe, Masuzyo and Munyinda, Masiliso and Muzazu, Seke and Caddy, Sarah L.},
  title = {A high-throughput rotavirus neutralization assay quantifies antibody responses beyond serum IgA in human infants},
  journal = {Journal of General Virology},
  year = {2026},
  volume = {107},
  number = {11},
  doi = {10.1099/jgv.0.002379}
}
Kostenlos starten →