EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia

John Merlino iD, Sophia Rizzo, Daniel Seed, Kimberly Chuen, Olivia Aitkens, Haejin Park, Avani Singh, Steven Siarakas

Access Microbiology · 01.07.2026 · 8 (7)

DOI: 10.1099/acmi.0.001106.v4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Access Microbiology, erschienen am 01.07.2026. Verfasst von John Merlino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology and Infectious Diseases, NSW Health Pathology, Concord Hospital, Sydney, Australia. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we compared and assessed the agreement of two commercial chromogenic agars, Brilliance Group B (BGB; Thermo Fisher, Australia) and ChromID STRB (bioMérieux, Australia), in the detection and presumptive identification of Group B streptococci (GBS; Streptococcus agalactiae ) by colour and later confirmed by MALDI-TOF MS (Bruker Australia). The sensitivity and specificity based on colour were 100 and 91% for BGB and 97 and 100% for ChromID STRB. The NPV (negative predictive value) for GBS on BGB was 100%, and the PPV (positive predictive value) was 73%. ChromID STRB had an NPV of 99% and a PPV of 100%. While both plates compared well in accuracy in the presumptive identification of GBS by colour, both plate media required the integration of MALDI-TOF MS for confirmatory identification. MALDI-TOF MS allowed accurate detection of GBS from both chromogenic plates with a score of >=2.0 after prior treatment with formic acid.

Schlagwörter

Stichwörter der Autor:innen

Brilliance Group BBrukerChromID STRBGroup B streptococciStreptococcus agalactiaechromogenic medialimit of detectionsensitivityspecificity

Autor:innen und Institutionen

  • Department of Microbiology and Infectious Diseases, NSW Health Pathology, Concord Hospital, Sydney, Australia.
  • Department of Infectious Disease and Immunology, School of Medical Sciences, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.

ORCID-Profile: John Merlino

Zitieren

APA

Merlino, J., Rizzo, S., Seed, D., Chuen, K., Aitkens, O., Park, H., Singh, A., & Siarakas, S. (2026). Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia. Access Microbiology, 8(7). https://doi.org/10.1099/acmi.0.001106.v4

Vancouver

Merlino J, Rizzo S, Seed D, Chuen K, Aitkens O, Park H, et al. Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia. Access Microbiology. 2026;8(7). doi:10.1099/acmi.0.001106.v4

BibTeX
@article{Merlino2026,
  author = {Merlino, John and Rizzo, Sophia and Seed, Daniel and Chuen, Kimberly and Aitkens, Olivia and Park, Haejin and Singh, Avani and Siarakas, Steven},
  title = {Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia},
  journal = {Access Microbiology},
  year = {2026},
  volume = {8},
  number = {7},
  doi = {10.1099/acmi.0.001106.v4}
}
Kostenlos starten →