Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia
Access Microbiology · 01.07.2026 · 8 (7)
DOI: 10.1099/acmi.0.001106.v4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Access Microbiology, erschienen am 01.07.2026. Verfasst von John Merlino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology and Infectious Diseases, NSW Health Pathology, Concord Hospital, Sydney, Australia. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In this study, we compared and assessed the agreement of two commercial chromogenic agars, Brilliance Group B (BGB; Thermo Fisher, Australia) and ChromID STRB (bioMérieux, Australia), in the detection and presumptive identification of Group B streptococci (GBS; Streptococcus agalactiae ) by colour and later confirmed by MALDI-TOF MS (Bruker Australia). The sensitivity and specificity based on colour were 100 and 91% for BGB and 97 and 100% for ChromID STRB. The NPV (negative predictive value) for GBS on BGB was 100%, and the PPV (positive predictive value) was 73%. ChromID STRB had an NPV of 99% and a PPV of 100%. While both plates compared well in accuracy in the presumptive identification of GBS by colour, both plate media required the integration of MALDI-TOF MS for confirmatory identification. MALDI-TOF MS allowed accurate detection of GBS from both chromogenic plates with a score of >=2.0 after prior treatment with formic acid.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Microbiology and Infectious Diseases, NSW Health Pathology, Concord Hospital, Sydney, Australia.
- Department of Infectious Disease and Immunology, School of Medical Sciences, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
ORCID-Profile: John Merlino
Zitieren
APA
Merlino, J., Rizzo, S., Seed, D., Chuen, K., Aitkens, O., Park, H., Singh, A., & Siarakas, S. (2026). Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia. Access Microbiology, 8(7). https://doi.org/10.1099/acmi.0.001106.v4
Vancouver
Merlino J, Rizzo S, Seed D, Chuen K, Aitkens O, Park H, et al. Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia. Access Microbiology. 2026;8(7). doi:10.1099/acmi.0.001106.v4
BibTeX
@article{Merlino2026,
author = {Merlino, John and Rizzo, Sophia and Seed, Daniel and Chuen, Kimberly and Aitkens, Olivia and Park, Haejin and Singh, Avani and Siarakas, Steven},
title = {Comparison of two chromogenic media: Brilliance Group B and ChromID STRB for the screening of Group B streptococci from an antenatal clinic in Sydney, Australia},
journal = {Access Microbiology},
year = {2026},
volume = {8},
number = {7},
doi = {10.1099/acmi.0.001106.v4}
}
EUVIMED