Bayesian Windkessel calibration using optimized zero-dimensional surrogate models
Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · 13.03.2025 · 383 (2292)
DOI: 10.1098/rsta.2024.0223 ↗Kurz gefasst
Fachartikel in der Zeitschrift Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, online erschienen am 13.03.2025. Verfasst von Jakob Richter und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Stanford University, Stanford, CA, USA. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: NHLBI NIH HHS, Stanford Maternal and Child Health Research Institute, National Science Foundation.
Abstract (Originalsprache)
Bayesian boundary condition (BC) calibration approaches from clinical measurements have successfully quantified inherent uncertainties in cardiovascular fluid dynamics simulations. However, estimating the posterior distribution for all BC parameters in three-dimensional (3D) simulations has been unattainable due to infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors: We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. Optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude in 72 publicly available vascular models. The optimized 0D models generalized well to a wide range of BCs. Using SMC, we evaluated the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model, which we validated against a 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Stanford University, Stanford, CA, USA.
- Institute for Computational Mechanics, Technical University of Munich, München, Bayern, Germany.
- Professorship for Data-Driven Materials Modeling, Technical University of Munich, München, Bayern, Germany.
- 2Institute for Computational and Mathematical Engineering, Stanford University, Stanford, CA, USA.
- Department of Applied and Computational Mathematics and Statistics, University of Notre Dame College of Science, Notre Dame, IN, USA.
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
ORCID-Profile: Daniele E Schiavazzi, Martin R Pfaller
Förderung
- NHLBI NIH HHS
- Stanford Maternal and Child Health Research Institute
- National Science Foundation
- HORIZON EUROPE European Research Council
- National Heart, Lung, and Blood Institute
Zitieren
APA
Richter, J., Nitzler, J., Pegolotti, L., Menon, K., Biehler, J., Wall, W. A., Schiavazzi, D. E., Marsden, A. L., & Pfaller, M. R. (2025). Bayesian Windkessel calibration using optimized zero-dimensional surrogate models. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 383(2292). https://doi.org/10.1098/rsta.2024.0223
Vancouver
Richter J, Nitzler J, Pegolotti L, Menon K, Biehler J, Wall WA, et al. Bayesian Windkessel calibration using optimized zero-dimensional surrogate models. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. 2025;383(2292). doi:10.1098/rsta.2024.0223
BibTeX
@article{Richter2025,
author = {Richter, Jakob and Nitzler, Jonas and Pegolotti, Luca and Menon, Karthik and Biehler, Jonas and Wall, Wolfgang A and Schiavazzi, Daniele E and Marsden, Alison L and Pfaller, Martin R},
title = {Bayesian Windkessel calibration using optimized zero-dimensional surrogate models},
journal = {Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences},
year = {2025},
volume = {383},
number = {2292},
doi = {10.1098/rsta.2024.0223}
}