EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A multi-angle continuous-flow injection analysis turbidimetric method for the determination of diphenhydramine hydrochloride

Inas H Al-Khafaji, Sarah Faris Hameed iD, Nagham Turkey

Royal Society Open Science · 12.08.2026 · 13 (8)

DOI: 10.1098/rsos.251842 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Royal Society Open Science, online erschienen am 12.08.2026. Verfasst von Inas H Al-Khafaji und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Baghdad College of Science, Baghdad, Iraq. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diphenhydramine hydrochloride was determined through a newly developed turbidimetric method on a home-designed continuous-flow injection analysis (CFIA) system. The principle of the method is based on the precipitation-induced signal enhancement, using potassium hexacyanoferrate (III) as a selective precipitating agent. The CFIA manifold uses a flow-through detection cell that consists of 12 white light-emitting diodes and three solar cells placed at 0, 90 and 180 degrees in order to track cumulative light scattering over a range of angles. The systematically optimized chemical and instrumental parameters were the reagent concentration, flow rate and sample volume to attain optimal sensitivity and reproducibility. The technique had good linearity (correlation coefficient, R = 0.9975) and per cent linearity (R2% = 99.49). The limit of detection was 255.325 ng/sample, calculated from serial dilution within the calibration range. Very high accuracy was achieved with a relative standard deviation (r.s.d.% < 0.4) of six replicates at 5 and 12 mmol l−1. Diphenhydramine hydrochloride in pharmaceutical tablets was successfully determined using the method. The method was found to be accurate, reliable and suitable for pharmaceutical quality control, as demonstrated by statistical comparisons with a conventional spectrophotometric technique using a paired t-test and a one-way ANOVA at the 95% confidence level.

Schlagwörter

Stichwörter der Autor:innen

diphenhydramine hydrochlorideflow injection analysismulti-angle photometric systemprecipitation-based quantificationturbidimetric detection

Autor:innen und Institutionen

  • Department of Chemistry, University of Baghdad College of Science, Baghdad, Iraq.
  • Department of Preparation and Training, Republic of Iraq Ministry of Education, Baghdad, Iraq.
  • Department of Chemistry, University of Baghdad, Baghdad, Iraq.

ORCID-Profile: Sarah Faris Hameed

Zitieren

APA

Al-Khafaji, I. H., Hameed, S. F., & Turkey, N. (2026). A multi-angle continuous-flow injection analysis turbidimetric method for the determination of diphenhydramine hydrochloride. Royal Society Open Science, 13(8). https://doi.org/10.1098/rsos.251842

Vancouver

Al-Khafaji IH, Hameed SF, Turkey N. A multi-angle continuous-flow injection analysis turbidimetric method for the determination of diphenhydramine hydrochloride. Royal Society Open Science. 2026;13(8). doi:10.1098/rsos.251842

BibTeX
@article{AlKhafaji2026,
  author = {Al-Khafaji, Inas H and Hameed, Sarah Faris and Turkey, Nagham},
  title = {A multi-angle continuous-flow injection analysis turbidimetric method for the determination of diphenhydramine hydrochloride},
  journal = {Royal Society Open Science},
  year = {2026},
  volume = {13},
  number = {8},
  doi = {10.1098/rsos.251842}
}