The sensible senseless person: a theoretical framework for clinical assessment of proprioception
Journal of The Royal Society Interface · 12.08.2026 · 23 (241)
DOI: 10.1098/rsif.2025.1345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of The Royal Society Interface, online erschienen am 12.08.2026. Verfasst von Yogev Koren und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Engineering and Management, Ben-Gurion University of the Negev , Be'er Sheva, Israel. Hauptthemen laut MEDLINE: Proprioception, Stroke, Models, Biological. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israeli Science Foundation, Lillian and David E. Feldman Research fund.
Abstract (Originalsprache)
Position-matching is a common task used to assess the sense of position, a sub-modality of proprioception. The ‘sensible senseless person’ (SSP), a theoretical construct that lacks sensory perception but is capable of logical inference, was developed to critically evaluate common outcome measures in such tasks. This framework reveals that traditional measures are influenced by task structure, strategic responses and the prior beliefs of the SSP. To address these limitations, we propose the Guess Index (GI), an outcome measure designed to ensure that the SSP receives the same score regardless of task or personal parameters. To demonstrate the GI's utility, we applied a simplified, clinically oriented position-matching task to healthy individuals and persons with stroke. Participants' performance often followed the SSP-predicted pattern. The GI correlated with traditional outcome measures, but was more sensitive to group differences and the only metric that classified persons with stroke above chance level in this dataset. Future studies should extend this framework to other proprioceptive sub-modalities and larger, more diverse populations before the GI can be considered a general index of proprioceptive adequacy with robust clinical cutoffs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Industrial Engineering and Management, Ben-Gurion University of the Negev , Be'er Sheva, Israel.
- Department of Computer Sciences and Applied Mathematics, Weizmann Institute of Science , Rehovot, Israel.
- Department of Mathematics, University of Michigan-Ann Arbor , Ann Arbor, MI, USA.
- The Lillian and David E. Feldman Research Centr, Adi Negev - Nahalat Eran Medical Centre , Ofakim, Israel.
ORCID-Profile: Yogev Koren, Asaf Cohen, Noy Goldhamer, Lior Shmuelof
Förderung
- Israeli Science Foundation
- Lillian and David E. Feldman Research fund
Zitieren
APA
Koren, Y., Cohen, A., Goldhamer, N., & Shmuelof, L. (2026). The sensible senseless person: a theoretical framework for clinical assessment of proprioception. Journal of The Royal Society Interface, 23(241). https://doi.org/10.1098/rsif.2025.1345
Vancouver
Koren Y, Cohen A, Goldhamer N, Shmuelof L. The sensible senseless person: a theoretical framework for clinical assessment of proprioception. Journal of The Royal Society Interface. 2026;23(241). doi:10.1098/rsif.2025.1345
BibTeX
@article{Koren2026,
author = {Koren, Yogev and Cohen, Asaf and Goldhamer, Noy and Shmuelof, Lior},
title = {The sensible senseless person: a theoretical framework for clinical assessment of proprioception},
journal = {Journal of The Royal Society Interface},
year = {2026},
volume = {23},
number = {241},
doi = {10.1098/rsif.2025.1345}
}
EUVIMED