EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-invasive load measurement in the human tibia via spectral analysis of flexural waves

Ali Yawar iD, Daniel H Aslan iD, Daniel E Lieberman iD

Journal of the Royal Society Interface · 2026

DOI: 10.1098/rsif.2025.1206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Royal Society Interface, 2026. Verfasst von Ali Yawar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Human Evolutionary Biology, Harvard University, Cambridge, MA, USA. Hauptthemen laut MEDLINE: Tibia, Models, Biological, Wearable Electronic Devices. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American School of Prehistoric Research (Harvard University).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Forces transmitted by bones are routinely studied in human biomechanics, but it is challenging to measure them non-invasively, especially outside of laboratory settings. We introduce a technique for non-invasive, in vivo measurement of tibial compressive force using flexural waves propagating in the tibia. Modelling the tibia as an axially compressed Euler–Bernoulli beam, we show that tibial flexural waves have load-dependent frequency spectra. Specifically, under physiological conditions, peak locations in the wave acceleration spectra vary linearly with the compressive force on the tibia and may be used as proxies for the compressive force. We test the validity of this technique using a proof-of-concept wearable system that generates flexural waves via a skin-mounted mechanical transducer and measures the spectra of these waves using a skin-mounted accelerometer. In agreement with beam theory, data from nine participants demonstrate linear relationships between tibial compressive force and spectral peak location, with Pearson correlation coefficients r=0.82-0.99 (mean r=0.93) for medial-lateral swaying and r=0.81-0.98 (mean r=0.93) for walking trials. This flexural wave-based technique could give rise to a new class of wearable sensors for non-invasive physiological bone load monitoring and measurement, impacting research in human locomotion and sports medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TibiaModels, BiologicalWearable Electronic DevicesHumansMaleFemaleAdultWeight-BearingBiomechanical Phenomena

Stichwörter der Autor:innen

flexural wavestibial loadingwearable sensors

Autor:innen und Institutionen

  • Department of Human Evolutionary Biology, Harvard University, Cambridge, MA, USA.

ORCID-Profile: Ali Yawar, Daniel H Aslan, Daniel E Lieberman

Förderung

  • American School of Prehistoric Research (Harvard University)

Zitieren

APA

Yawar, A., Aslan, D. H., & Lieberman, D. E. (2026). Non-invasive load measurement in the human tibia via spectral analysis of flexural waves. Journal of the Royal Society Interface. https://doi.org/10.1098/rsif.2025.1206

Vancouver

Yawar A, Aslan DH, Lieberman DE. Non-invasive load measurement in the human tibia via spectral analysis of flexural waves. Journal of the Royal Society Interface. 2026. doi:10.1098/rsif.2025.1206

BibTeX
@article{Yawar2026,
  author = {Yawar, Ali and Aslan, Daniel H and Lieberman, Daniel E},
  title = {Non-invasive load measurement in the human tibia via spectral analysis of flexural waves},
  journal = {Journal of the Royal Society Interface},
  year = {2026},
  doi = {10.1098/rsif.2025.1206}
}
Kostenlos starten →