EUVIMEDEUVIMED entdecken
Crossref

Wearable ankle activity monitor overestimates energy expenditure during ecological walking tasks in individuals with stroke and healthy adults

Amine Guediri, Maxence Compagnat, Mathilde Baillargeat, Lucas Firmin, Jean-Christophe Daviet, Stéphane Mandigout

International Journal of Rehabilitation Research · 2026-09 · 49 (3) · 197-205

DOI: 10.1097/mrr.0000000000000708 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Rehabilitation Research, online erschienen am 28.07.2026. Verfasst von Amine Guediri und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Limoges, HAVAE, UR 20217, Limoges. Hauptthemen laut MEDLINE: Energy Metabolism, Walking, Stroke, Stroke Rehabilitation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: CHU de Limoges.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Assessment of physical activity intensity is essential for guiding rehabilitation after stroke. Wearable activity monitors are used to estimate energy expenditure during walking; however, their validity in stroke populations under real-life walking conditions remains uncertain. This study aimed to evaluate the validity of an ActiGraph GT3X for estimating energy expenditure during walking tasks in stroke survivors using indirect calorimetry as the reference method. Thirty stroke survivors and 30 healthy controls performed indoor and outdoor walking tasks, including overground walking, stair ascent and descent, irregular terrain walking, and uphill and downhill walking. Energy expenditure expressed in metabolic equivalents was measured using the ActiGraph GT3X worn at the ankle and a portable gas exchange analyzer. Agreement between methods was assessed using Bland–Altman analyses and linear regression models. The ActiGraph GT3X overestimated energy expenditure across most walking tasks in both groups, with percentage differences ranging from 25.7 to 112% in stroke survivors and from 18.1 to 149.1% in healthy controls. In stroke survivors, walking speed was significantly associated with the difference in energy expenditure (ActiGraph GT3X – indirect calorimetry) across most tasks, with higher speeds leading to greater overestimation (e.g. β = 9.01, P < 0.001, R 2 = 0.41 for stair descent). In healthy controls, this association was observed only for selected tasks, including overground walking and stair descent. These findings indicate that the ActiGraph GT3X has limited validity for energy expenditure estimation during ecological walking tasks. Although the device may provide relative indicators of effort, its outputs should be interpreted with caution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Energy MetabolismWalkingStrokeStroke RehabilitationWearable Electronic DevicesActigraphyHumansFemaleMaleMiddle AgedAgedAdultCalorimetry, IndirectAnkleReproducibility of Results

Stichwörter der Autor:innen

accelerometryenergy expenditurestrokewalking

Autor:innen und Institutionen

  • University of Limoges, HAVAE, UR 20217, Limoges.
  • University of Bordeaux, INSERM, BPH, U1219, Bordeaux.
  • Department PMR, CHU Limoges, Limoges, France.

Förderung

  • CHU de Limoges

Zitieren

APA

Guediri, A., Compagnat, M., Baillargeat, M., Firmin, L., Daviet, J. C., & Mandigout, S. (2026). Wearable ankle activity monitor overestimates energy expenditure during ecological walking tasks in individuals with stroke and healthy adults. International Journal of Rehabilitation Research, 49(3), 197-205. https://doi.org/10.1097/mrr.0000000000000708

Vancouver

Guediri A, Compagnat M, Baillargeat M, Firmin L, Daviet JC, Mandigout S. Wearable ankle activity monitor overestimates energy expenditure during ecological walking tasks in individuals with stroke and healthy adults. International Journal of Rehabilitation Research. 2026;49(3):197-205. doi:10.1097/mrr.0000000000000708

BibTeX
@article{Guediri2026,
  author = {Guediri, Amine and Compagnat, Maxence and Baillargeat, Mathilde and Firmin, Lucas and Daviet, Jean-Christophe and Mandigout, Stéphane},
  title = {Wearable ankle activity monitor overestimates energy expenditure during ecological walking tasks in individuals with stroke and healthy adults},
  journal = {International Journal of Rehabilitation Research},
  year = {2026},
  volume = {49},
  number = {3},
  pages = {197--205},
  doi = {10.1097/mrr.0000000000000708}
}
Kostenlos starten →