EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Transplant Thickness and Asymmetry Related to Best-Corrected Visual Acuity After Ultra-Thin Descemet Stripping Automated Endothelial Keratoplasty

Henrik Sørensen, Morten Brok Molbech Madsen, Ebbe Toftgaard Poulsen, Anders Ivarsen, Jesper Hjortdal

Eye Banking and Corneal Transplantation · 2026-03 · 5 (1)

DOI: 10.1097/ebct.0000000000000049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eye Banking and Corneal Transplantation, 2026-03. Verfasst von Henrik Sørensen und 4 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate how transplant thickness and transplant asymmetry may influence best-corrected visual acuity (BCVA) after ultra-thin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) procedure by using data from a controlled trial investigating BCVA after UT-DSAEK.

Methods

Participants with Fuchs endothelial dystrophy underwent UT-DSAEK with eye bank prepared grafts. Twelve months postoperatively, follow-up evaluations, including BCVA, were conducted. From Optical Coherence Tomography images of the prepared donor grafts, transplant thickness was measured centrally and 1, 2, 3, and 4 mm from the center in both directions along 4 meridians to assess the entire graft. Regression analyses were used to analyze the relation between BCVA and the 2 variables: thickness at the thinnest point of the transplant and transplant asymmetry estimated by the standard deviation of thickness variation.

Results

Among 33 grafts implanted in 33 patients, the mean BCVA at 12 months was 80.4 early treatment diabetic retinopathy study letters. Mean thickness at the thinnest point was 74.1 μm (range: 32–114, SD = 22.6). Thickness at the thinnest point was significantly correlated with better BCVA at 12 months ( P =

Zitieren

APA

Sørensen, H., Madsen, M. B. M., Poulsen, E. T., Ivarsen, A., & Hjortdal, J. (2026). Transplant Thickness and Asymmetry Related to Best-Corrected Visual Acuity After Ultra-Thin Descemet Stripping Automated Endothelial Keratoplasty. Eye Banking and Corneal Transplantation, 5(1). https://doi.org/10.1097/ebct.0000000000000049

Vancouver

Sørensen H, Madsen MBM, Poulsen ET, Ivarsen A, Hjortdal J. Transplant Thickness and Asymmetry Related to Best-Corrected Visual Acuity After Ultra-Thin Descemet Stripping Automated Endothelial Keratoplasty. Eye Banking and Corneal Transplantation. 2026;5(1). doi:10.1097/ebct.0000000000000049

BibTeX
@article{Srensen2026,
  author = {Sørensen, Henrik and Madsen, Morten Brok Molbech and Poulsen, Ebbe Toftgaard and Ivarsen, Anders and Hjortdal, Jesper},
  title = {Transplant Thickness and Asymmetry Related to Best-Corrected Visual Acuity After Ultra-Thin Descemet Stripping Automated Endothelial Keratoplasty},
  journal = {Eye Banking and Corneal Transplantation},
  year = {2026},
  volume = {5},
  number = {1},
  doi = {10.1097/ebct.0000000000000049}
}
Kostenlos starten →