Donor Cornea Storage Temperature: Investigation of the Time Period Immediately Before Cornea Transplantation Surgery

Karl Maeser Andersen, Joseph Lin Da, Walter Matthew Petroll, William Hatcher Waldrop

Eye Banking and Corneal Transplantation · 2024

DOI: 10.1097/ebct.0000000000000023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eye Banking and Corneal Transplantation, 2024. Verfasst von Karl Maeser Andersen und 3 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Donor cornea storage temperature seems to affect tissue viability; however, the time period between removal from storage and transplant surgery has not been explored. We investigated the possible impact time at room temperature in the operating room may have on endothelial cell density (ECD) and corneal thickness (CT).

Methods

In our simulation, transplant-ineligible corneas underwent 1 of 4 room temperature protocols. ECD (by specular microscopy) and CT (by anterior segment optical coherence tomography [OCT]), measured before and after protocols, were used to explore possible effects of time at room temperature. Control group tissue resided at room temperature only long enough for warming and subsequent ECD and CT measurements.

Results

Corneas underwent one of the following protocols: 1) 17 (±1) minutes at room temperature (for baseline OCT measurements; n = 13) followed by 23 minutes at 35°C (to facilitate specular imaging, conducted for all 4 protocols), 2) 60 (±1) minutes (1 hour; n = 8) at room temperature, 3) 187 (±1) minutes (approximately 3 hours; n = 7) at room temperature, and 4) 416 (±1) minutes (approximately 7 hours; n = 7). Statistical analysis showed no significant difference in ECD change ( P = 0.353) or CT change ( P = 0.415) between protocol groups. Controlling for donor age and death-to-preservation time rendered no statistical significance.

Conclusions

Time at room temperature did not seem to significantly influence ECD or CT measured soon after warming. Studies exploring ECD postoperatively and long-term graft survival are needed to assess the possible clinical impact of preoperative time at room temperature.

Zitieren

APA

Andersen, K. M., Da, J. L., Petroll, W. M., & Waldrop, W. H. (2024). Donor Cornea Storage Temperature: Investigation of the Time Period Immediately Before Cornea Transplantation Surgery. Eye Banking and Corneal Transplantation. https://doi.org/10.1097/ebct.0000000000000023

Vancouver

Andersen KM, Da JL, Petroll WM, Waldrop WH. Donor Cornea Storage Temperature: Investigation of the Time Period Immediately Before Cornea Transplantation Surgery. Eye Banking and Corneal Transplantation. 2024. doi:10.1097/ebct.0000000000000023

BibTeX
@article{Andersen2024,
  author = {Andersen, Karl Maeser and Da, Joseph Lin and Petroll, Walter Matthew and Waldrop, William Hatcher},
  title = {Donor Cornea Storage Temperature: Investigation of the Time Period Immediately Before Cornea Transplantation Surgery},
  journal = {Eye Banking and Corneal Transplantation},
  year = {2024},
  doi = {10.1097/ebct.0000000000000023}
}
Kostenlos starten →