Qualitative Blade Topology in Donor Cornea Punches and Corresponding Endothelial Cell Loss in PK and DMEK Grafts

Megan M. W. Straiko, Claudia S. López, Rebecca Hubbs, Phillip K. Dye, Khoa D. Tran

Eye Banking and Corneal Transplantation · 2024

DOI: 10.1097/ebct.0000000000000022 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eye Banking and Corneal Transplantation, 2024. Verfasst von Megan M. W. Straiko und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Two commonly used donor cornea punches were assessed using quantification of peripheral endothelial cell loss (ECL) and scanning electron microscopy (SEM) of blade topology and associated features on donor grafts.

Methods

Penetrating keratoplasty (PK) (n = 8 pairs) and Descemet membrane endothelial keratoplasty (DMEK) (n = 8 pairs) grafts were prepared from mate donor corneas using Moria Busin or Corza Barron donor cornea punches (all punches were 7.5 mm) and analyzed for global and peripheral ECL. Punches were examined by SEM and subsequently used to prepare PK grafts from mate donor corneas (n = 3 pairs) that were also assessed by SEM.

Results

For PK grafts, peripheral ECL caused by Busin and Barron punches was 4.2% ± 0.6% and 4.0% ± 0.9% ( P = 0.62), respectively. For DMEK grafts, peripheral ECL caused by Busin and Barron punches was 3.6% ± 1.9% and 3.0% ± 1.3% ( P = 0.48), respectively. SEM analysis of the Busin punch identified a rolled blade with a seam; the Barron punch is created from full rod stock and is seamless. Busin punch PK grafts have a ridge of stromal tissue that was not observed in the Barron PK grafts. Both punches exhibit anomalies along the blade edge, and the stroma of both grafts exhibited “drag lines.” Conclusions: Both punches caused similar and minimal ECL. In PK grafts, the seam of the Busin punch may be the source of the observed uneven stromal surface. Striations and debris on the cutting surfaces of both punches may produce drag lines in cut stroma. These topological features may contribute to uneven donor–recipient tissue apposition, leading to astigmatism after PK.

Zitieren

APA

Straiko, M. M. W., López, C. S., Hubbs, R., Dye, P. K., & Tran, K. D. (2024). Qualitative Blade Topology in Donor Cornea Punches and Corresponding Endothelial Cell Loss in PK and DMEK Grafts. Eye Banking and Corneal Transplantation. https://doi.org/10.1097/ebct.0000000000000022

Vancouver

Straiko MMW, López CS, Hubbs R, Dye PK, Tran KD. Qualitative Blade Topology in Donor Cornea Punches and Corresponding Endothelial Cell Loss in PK and DMEK Grafts. Eye Banking and Corneal Transplantation. 2024. doi:10.1097/ebct.0000000000000022

BibTeX
@article{Straiko2024,
  author = {Straiko, Megan M. W. and López, Claudia S. and Hubbs, Rebecca and Dye, Phillip K. and Tran, Khoa D.},
  title = {Qualitative Blade Topology in Donor Cornea Punches and Corresponding Endothelial Cell Loss in PK and DMEK Grafts},
  journal = {Eye Banking and Corneal Transplantation},
  year = {2024},
  doi = {10.1097/ebct.0000000000000022}
}
Kostenlos starten →