Comparison of Corneal Endothelial Cell Density and Morphology With Optisol-GS and Life4C Storage Media in the Eye Bank: A 5-Year Retrospective Analysis

Rubens Petithomme, Ranit Karmakar, John Lohmeier, Staci Terrin, Ellen H Koo, Allen O Eghrari

Eye Banking and Corneal Transplantation · 2023

DOI: 10.1097/ebct.0000000000000019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eye Banking and Corneal Transplantation, 2023. Verfasst von Rubens Petithomme und 5 weiteren Autor:innen. Beteiligte Einrichtung: Howard University School of Medicine, Washington, DC, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Optisol-GS and Life4C are corneal storage media used by eye banks worldwide. We sought to determine whether either solution was associated with superior corneal endothelial cell density (ECD) or morphology in a large cohort of donor corneas.

Methods

From January 2016 to December 2020, 10,316 corneas from 5624 unique donors were acquired and analyzed at Rocky Mountain Lions Eye Bank. In April 2019, Life4C replaced Optisol-GS as the sole storage medium. We compared ECD and morphology before and after April 2019 and excluded corneas processed within the transition period. Univariable and multivariable regression analyses accounted for age, sex, tobacco use, heavy alcohol use, and diabetes. Only right corneas were analyzed to account for the correlation between eyes.

Results

Of 5042 right corneas analyzed, 3486 were stored in Optisol-GS and 1556 in Life4C. There was no significant difference in ECD across groups (2794 vs. 2793 cells/mm 2 in Optisol-GS and Life4C, P = 0.88). In multivariate analyses, there was no significant difference in corneal ECD (0.6 cells/mm 2 higher with Life4C, P = 0.96) or hexagonality (0.22% higher with Life4C, P = 0.31). However, the coefficient of variation was significantly lower in the Life4C group (−0.0039, P = 0.03). After adjustment for above factors, corneas in Life4C demonstrated a 3.1% decreased likelihood of exhibiting coefficient of variation (CV) values greater than 0.40 ( P = 0.009).

Conclusions

This study demonstrates comparable and favorable outcomes using both storage media and confirms their overall efficacy. The decreased CV in Life4C is not of clinically significant magnitude but merits further research in clinical and long-term settings.

Schlagwörter

Stichwörter der Autor:innen

Cornea TransplantationCorneal EndotheliumEye BankLife4COptisol

Autor:innen und Institutionen

  • Howard University School of Medicine, Washington, DC, USA.
  • Michigan Technological University, Houghton, Michigan, USA.
  • Rocky Mountain Lions Eye Bank, Colorado, USA.
  • Bascom Palmer Eye Institute, West Palm Beach, Florida, USA.
  • Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

Förderung

  • NEI NIH HHS

Zitieren

APA

Petithomme, R., Karmakar, R., Lohmeier, J., Terrin, S., Koo, E. H., & Eghrari, A. O. (2023). Comparison of Corneal Endothelial Cell Density and Morphology With Optisol-GS and Life4C Storage Media in the Eye Bank: A 5-Year Retrospective Analysis. Eye Banking and Corneal Transplantation. https://doi.org/10.1097/ebct.0000000000000019

Vancouver

Petithomme R, Karmakar R, Lohmeier J, Terrin S, Koo EH, Eghrari AO. Comparison of Corneal Endothelial Cell Density and Morphology With Optisol-GS and Life4C Storage Media in the Eye Bank: A 5-Year Retrospective Analysis. Eye Banking and Corneal Transplantation. 2023. doi:10.1097/ebct.0000000000000019

BibTeX
@article{Petithomme2023,
  author = {Petithomme, Rubens and Karmakar, Ranit and Lohmeier, John and Terrin, Staci and Koo, Ellen H and Eghrari, Allen O},
  title = {Comparison of Corneal Endothelial Cell Density and Morphology With Optisol-GS and Life4C Storage Media in the Eye Bank: A 5-Year Retrospective Analysis},
  journal = {Eye Banking and Corneal Transplantation},
  year = {2023},
  doi = {10.1097/ebct.0000000000000019}
}
Kostenlos starten →