Fachartikel in der Zeitschrift Cardiopulmonary Physical Therapy Journal, 2018-10. Verfasst von Christopher Brown und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Physical Therapy, Texas Woman's University, Houston, TX. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

(1) Determine whether ultrasonography can detect differences in diaphragm contractility between body positions. (2) Perform reliability analysis of diaphragm thickness measurements in each test condition.

Methods

We used a repeated-measures experimental design with 45 healthy adults where 3 B-mode ultrasound images were collected at peak-inspiration and end-expiration in supine, sitting, and standing. Mean diaphragm thickening fractions were calculated for each test position. Statistical significance was tested using 1-way repeated-measures analysis of variance with planned comparisons. For reliability analysis, the intraclass correlation coefficient (3, 3) was calculated.

Results

Mean diaphragm thickening fraction increased from 60.2% (95% confidence interval [CI] 53.0%, 67.9%) in supine, to 96.5% (95% CI 83.2%, 109.9%) while seated and to 173.8% (95% CI 150.5%, 197.1%) while standing. Body position was a significant factor overall ( P < .001), as were comparisons between each individual position ( P < .001). Intraobserver reliability was excellent (>0.93) for all body positions tested.

Conclusions

Ultrasound imaging detected positional differences in diaphragm contractility. The effect of gravitational loading on diaphragm length-tension, and body position-mediated changes in intra-abdominal pressure may explain the differences found. Future research should address methodological concerns and apply this method to patients participating in early mobilization programs in the intensive care unit.

Schlagwörter

Stichwörter der Autor:innen

diaphragmpatient positioningultrasonography

Autor:innen und Institutionen

  • School of Physical Therapy, Texas Woman's University, Houston, TX.

Zitieren

APA

Brown, C., Tseng, S. C., Mitchell, K., & Roddey, T. (2018). Body Position Affects Ultrasonographic Measurement of Diaphragm Contractility. Cardiopulmonary Physical Therapy Journal, 29(4), 166-172. https://doi.org/10.1097/cpt.0000000000000083

Vancouver

Brown C, Tseng SC, Mitchell K, Roddey T. Body Position Affects Ultrasonographic Measurement of Diaphragm Contractility. Cardiopulmonary Physical Therapy Journal. 2018;29(4):166-172. doi:10.1097/cpt.0000000000000083

BibTeX
@article{Brown2018,
  author = {Brown, Christopher and Tseng, Shih-Chiao and Mitchell, Katy and Roddey, Toni},
  title = {Body Position Affects Ultrasonographic Measurement of Diaphragm Contractility},
  journal = {Cardiopulmonary Physical Therapy Journal},
  year = {2018},
  volume = {29},
  number = {4},
  pages = {166--172},
  doi = {10.1097/cpt.0000000000000083}
}
Kostenlos starten →