EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Accuracy of Smartphone Corneal Photography for Detection of Corneal Opacities in a Resource-Limited Setting: A Community-Based Study

Binh Cao, Puspa Giri, Raghunandan Byanju, Sangita Pradhan, Gopal Bhandari, Sadhan Bhandari, Ram Prasad Kandel, Bimal Poudyal, John A Gonzales, Muthiah Srinivasan, Madan Upadhyay, John P Whitcher und 3 weitere

Cornea Open · 2023

DOI: 10.1097/coa.0000000000000018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cornea Open, 2023. Verfasst von Binh Cao und 14 weiteren Autor:innen. Beteiligte Einrichtung: Francis I Proctor Foundation, University of California, San Francisco, USA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FIC NIH HHS, NEI NIH HHS, Fogarty International Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the diagnostic accuracy of smartphone corneal photography in detecting corneal opacities in a community-based setting.

Methods

A case-control, diagnostic accuracy study was nested in a cluster-randomized trial of a corneal ulcer prevention intervention in Nepal. Smartphone corneal photography was performed annually on community members self-reporting a potential risk factor for a corneal infection. Corneal photographs were graded for the presence or absence of an opacity. All cases with an opacity on smartphone photography and an equal number of controls were invited for a comprehensive eye examination with a slit lamp biomicroscope at an eye hospital. A mobile team visited participants unable to come to the hospital, conducting a limited examination with a penlight.

Results

Of 1332 study participants (666 cases and 666 controls), 1097 had a penlight examination (535 cases and 562 controls) and 191 had a slit lamp examination (120 cases and 71 controls). When penlight examination was considered the reference standard, smartphone diagnosis of a corneal opacity had a positive predictive value (PPV) of 47% (95% confidence interval 43%–52%) and negative predictive value (NPV) of 95% (93%–97%). When slit lamp examination was considered the reference standard, the overall PPV and NPV were 71% (62%–78%) and 80% (70%–88%), respectively. The NPV was greater for detection of opacities >1 mm, estimated at 95% (90%–98%).

Conclusions

Corneal photography performed in a resource-limited community-based setting using a smartphone coupled to an external attachment had acceptable diagnostic accuracy for detection of corneal opacities large enough to be clinically meaningful.

Schlagwörter

Stichwörter der Autor:innen

Corneal opacitycommunitydiagnostic accuracysmartphone photography

Autor:innen und Institutionen

  • Francis I Proctor Foundation, University of California, San Francisco, USA.
  • Bharatpur Eye Hospital, Bharatpur, Nepal.
  • Seva Foundation, Berkeley, California, USA.
  • Department of Ophthalmology, University of California, San Francisco, USA.
  • Department of Cornea and Refractive Surgery, Aravind Eye Hospital, Madurai, India.
  • BP Eye Foundation, Children's Hospital for Eye, Ear, and Rehabilitation Services (CHEERS), Kathmandu, Nepal.

Förderung

  • FIC NIH HHS
  • NEI NIH HHS
  • Fogarty International Center
  • National Eye Institute

Zitieren

APA

Cao, B., Giri, P., Byanju, R., Pradhan, S., Bhandari, G., Bhandari, S., Kandel, R. P., Poudyal, B., Gonzales, J. A., Srinivasan, M., Upadhyay, M., Whitcher, J. P., O'Brien, K. S., Lietman, T. M., & Keenan, J. D. (2023). Diagnostic Accuracy of Smartphone Corneal Photography for Detection of Corneal Opacities in a Resource-Limited Setting: A Community-Based Study. Cornea Open. https://doi.org/10.1097/coa.0000000000000018

Vancouver

Cao B, Giri P, Byanju R, Pradhan S, Bhandari G, Bhandari S, et al. Diagnostic Accuracy of Smartphone Corneal Photography for Detection of Corneal Opacities in a Resource-Limited Setting: A Community-Based Study. Cornea Open. 2023. doi:10.1097/coa.0000000000000018

BibTeX
@article{Cao2023,
  author = {Cao, Binh and Giri, Puspa and Byanju, Raghunandan and Pradhan, Sangita and Bhandari, Gopal and Bhandari, Sadhan and Kandel, Ram Prasad and Poudyal, Bimal and Gonzales, John A and Srinivasan, Muthiah and Upadhyay, Madan and Whitcher, John P and O'Brien, Kieran S and Lietman, Thomas M and Keenan, Jeremy D},
  title = {Diagnostic Accuracy of Smartphone Corneal Photography for Detection of Corneal Opacities in a Resource-Limited Setting: A Community-Based Study},
  journal = {Cornea Open},
  year = {2023},
  doi = {10.1097/coa.0000000000000018}
}
Kostenlos starten →