Fracture of a metal backed patellofemoral component overlying an osteolytic lesion

Gregorio Baek, Ji Won Lee, Christopher Jaicks, Thomas Peacock, Beruk Sherif, Henry R. Boucher

Current Orthopaedic Practice · 2026-07 · 37 (4)

DOI: 10.1097/bco.0000000000001352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Current Orthopaedic Practice, 2026-07. Verfasst von Gregorio Baek und 5 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The second-generation patellofemoral component used in total knee arthroplasty (TKA) uses porous tantalum, which has lower tensile and yield strengths compared to titanium used in the first-generation implant. However, there is a paucity of studies investigating the complications in either generation. This case involves a female patient with a history of right TKA with a second-generation metal backed patellofemoral component who presented with right knee pain. Exam findings demonstrated positive patellofemoral grind test, medial joint line tenderness, and end-range flexion and extension pain. Radiographs showed a fracture of the metal backing of the proximal lateral patellofemoral component. A revision TKA was performed. Intraoperatively, there was a bony defect in the superior lateral patella underneath the area of the fractured metal patellar component. We hypothesize that the bony defect of the patella resulted in a stress point in the metal backing of the patellofemoral component, eventually causing a fatigue fracture after sustaining repetitive bending forces. The patellar component was revised with a cemented component, which also addressed the bony defect. Surgeons using a cementless metal backed patellofemoral component should take measures to ameliorate any stress points by ensuring circumferential support of the component.

Zitieren

APA

Baek, G., Lee, J. W., Jaicks, C., Peacock, T., Sherif, B., & Boucher, H. R. (2026). Fracture of a metal backed patellofemoral component overlying an osteolytic lesion. Current Orthopaedic Practice, 37(4). https://doi.org/10.1097/bco.0000000000001352

Vancouver

Baek G, Lee JW, Jaicks C, Peacock T, Sherif B, Boucher HR. Fracture of a metal backed patellofemoral component overlying an osteolytic lesion. Current Orthopaedic Practice. 2026;37(4). doi:10.1097/bco.0000000000001352

BibTeX
@article{Baek2026,
  author = {Baek, Gregorio and Lee, Ji Won and Jaicks, Christopher and Peacock, Thomas and Sherif, Beruk and Boucher, Henry R.},
  title = {Fracture of a metal backed patellofemoral component overlying an osteolytic lesion},
  journal = {Current Orthopaedic Practice},
  year = {2026},
  volume = {37},
  number = {4},
  doi = {10.1097/bco.0000000000001352}
}
Kostenlos starten →