A quality improvement initiative to increase kangaroo mother care duration in a tertiary neonatal intensive care unit in Northern India
Journal of Tropical Pediatrics · 09.10.2026 · 72 (6)
DOI: 10.1093/tropej/fmag079 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Tropical Pediatrics, online erschienen am 16.11.2026. Verfasst von Arohi Gupta und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 226014, India. Hauptthemen laut MEDLINE: Quality Improvement, Kangaroo-Mother Care Method, Intensive Care Units, Neonatal. Die Arbeit nennt 14 Literaturangaben.
Themen: Neonatologie, Intensivpflege
Abstract (Originalsprache)
Kangaroo mother care (KMC) reduces mortality and morbidity in preterm and low-birth-weight infants, but daily duration in Indian neonatal units often falls short of the World Health Organization minimum of 8 hours. In our Level III neonatal unit, a baseline audit found a mean KMC duration of 4 hours/day, and infants on non-invasive respiratory support rarely received KMC. Using the Point-of-Care Quality Improvement framework, three Plan–Do–Study–Act cycles over 12 weeks (December 2024–February 2025) addressed staff training for KMC during continuous positive airway pressure (CPAP) or high-flow nasal cannula (HFNC), family engagement and workflow, and behavioural reinforcement. A 12-week sustenance phase followed. Eligible infants weighed <2000 g, were haemodynamically stable, and were not on invasive ventilation or phototherapy. KMC hours were taken from shift-wise nursing records. The outcome was mean daily KMC duration per infant, analysed on a run chart. All 20 eligible infants received KMC, 12 (60%) while on CPAP or HFNC. Median per-infant KMC duration was 9.75 hours/day (interquartile range 8.8–10.6), compared with 4 hours/day at baseline; 17 infants (85%) averaged at least 8 hours/day. Duration was lower among infants who started KMC during the second and third cycles and returned to the median during the sustenance phase. No hypothermia or device dislodgement occurred; one infant had an apnoeic episode. A people-centred quality improvement initiative using existing unit resources was associated with longer daily KMC, including in infants on non-invasive respiratory support, and the gain was maintained over 12 weeks. The 12-hour target could not be reached.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Neonatology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 226014, India.
ORCID-Profile: Akanksha Verma, Fajia Farhath, Kirti M Naranje
Zitieren
APA
Gupta, A., Verma, A., Paul, A., Singh Solanki, P., Farhath, F., Naranje, K. M., Singh, A., Kumar, S., & Rajput, S. (2026). A quality improvement initiative to increase kangaroo mother care duration in a tertiary neonatal intensive care unit in Northern India. Journal of Tropical Pediatrics, 72(6). https://doi.org/10.1093/tropej/fmag079
Vancouver
Gupta A, Verma A, Paul A, Singh Solanki P, Farhath F, Naranje KM, et al. A quality improvement initiative to increase kangaroo mother care duration in a tertiary neonatal intensive care unit in Northern India. Journal of Tropical Pediatrics. 2026;72(6). doi:10.1093/tropej/fmag079
BibTeX
@article{Gupta2026,
author = {Gupta, Arohi and Verma, Akanksha and Paul, Abhishek and Singh Solanki, Preeti and Farhath, Fajia and Naranje, Kirti M and Singh, Anita and Kumar, Sunil and Rajput, Shikha},
title = {A quality improvement initiative to increase kangaroo mother care duration in a tertiary neonatal intensive care unit in Northern India},
journal = {Journal of Tropical Pediatrics},
year = {2026},
volume = {72},
number = {6},
doi = {10.1093/tropej/fmag079}
}
EUVIMED